12 DATA USED FOR POSITIONING CONTROL
12.2 List of Buffer Memory Addresses
Interrupt setting
Address
Decimal (Hexadecimal)
Name
Default
value
Auto
refresh
Memory area
Common for Axis 1 to 4
55000 (D6D8H)
Interrupt setting
No.1
[Md.65] Interrupt factor detection flag
0
Interrupt setting
data
55064 (D718H)
[Cd.50] Interrupt factor mask
0
55128 (D758H)
[Cd.51] Interrupt factor reset request
0
55192 (D798H)
[Pr.900] Interrupt factor setting
0
55256 (D7D8H)
[Pr.901] Axis No. for interrupt factor
0
55001 (D6D9H)
Interrupt setting
No.2
[Md.65] Interrupt factor detection flag
0
55065 (D719H)
[Cd.50] Interrupt factor mask
0
55129 (D759H)
[Cd.51] Interrupt factor reset request
0
55193 (D799H)
[Pr.900] Interrupt factor setting
0
55257 (D7D9H)
[Pr.901] Axis No. for interrupt factor
0
55002 (D6DAH)
Interrupt setting
No.3
[Md.65] Interrupt factor detection flag
0
55066 (D71AH)
[Cd.50] Interrupt factor mask
0
55130 (D75AH)
[Cd.51] Interrupt factor reset request
0
55194 (D79AH)
[Pr.900] Interrupt factor setting
0
55258 (D7DAH)
[Pr.901] Axis No. for interrupt factor
0
55003 (D6DBH)
Interrupt setting
No.4
[Md.65] Interrupt factor detection flag
0
55067 (D71BH)
[Cd.50] Interrupt factor mask
0
55131 (D75BH)
[Cd.51] Interrupt factor reset request
0
55195 (D79BH)
[Pr.900] Interrupt factor setting
0
55259 (D7DBH)
[Pr.901] Axis No. for interrupt factor
0
55004 (D6DCH)
Interrupt setting
No.5
[Md.65] Interrupt factor detection flag
0
55068 (D71CH)
[Cd.50] Interrupt factor mask
0
55132 (D75CH)
[Cd.51] Interrupt factor reset request
0
55196 (D79CH)
[Pr.900] Interrupt factor setting
0
55260 (D7DCH)
[Pr.901] Axis No. for interrupt factor
0
55005 (D6DDH)
Interrupt setting
No.6
[Md.65] Interrupt factor detection flag
0
55069 (D71DH)
[Cd.50] Interrupt factor mask
0
55133 (D75DH)
[Cd.51] Interrupt factor reset request
0
55197 (D79DH)
[Pr.900] Interrupt factor setting
0
55261 (D7DDH)
[Pr.901] Axis No. for interrupt factor
0
55006 (D6DEH)
Interrupt setting
No.7
[Md.65] Interrupt factor detection flag
0
55070 (D71EH)
[Cd.50] Interrupt factor mask
0
55134 (D75EH)
[Cd.51] Interrupt factor reset request
0
55198 (D79EH)
[Pr.900] Interrupt factor setting
0
55262 (D7DEH)
[Pr.901] Axis No. for interrupt factor
0
55007 (D6DFH)
Interrupt setting
No.8
[Md.65] Interrupt factor detection flag
0
55071 (D71FH)
[Cd.50] Interrupt factor mask
0
55135 (D75FH)
[Cd.51] Interrupt factor reset request
0
55199 (D79FH)
[Pr.900] Interrupt factor setting
0
55263 (D7DFH)
[Pr.901] Axis No. for interrupt factor
0
55008 (D6E0H)
Interrupt setting
No.9
[Md.65] Interrupt factor detection flag
0
55072 (D720H)
[Cd.50] Interrupt factor mask
0
55136 (D760H)
[Cd.51] Interrupt factor reset request
0
55200 (D7A0H)
[Pr.900] Interrupt factor setting
0
55264 (D7E0H)
[Pr.901] Axis No. for interrupt factor
0
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......