APPX
Appendix 3 Added and Changed Functions
1097
A
Appendix 3
Added and Changed Functions
The functions added or changed with the CPU module and engineering tool, and the supported CPU modules' firmware
version and engineering tool software version are given below.
• The firmware version can be confirmed with module diagnosis (CPU diagnosis). Refer to the User's Manual (Hardware) for
the CPU module in use for details on diagnosing the module (CPU diagnosis).
• Refer to the
GX Works3 Operating Manual for details on the software version.
*1 Supported with CPU module serial No. 158**** and above.
*2 Supported with CPU module serial No. 16Y**** and above.
Add/Change Function
Supported CPU module
firmware version
Supported engineering
tool software version
Reference
The RS2 instruction is supported.
"1.014" and above
"1.005F" and above
The SEGD(P) instruction is supported.
"1.014" and above
"1.007H" and above
The SEGL instruction is supported.
"1.014" and above
"1.007H" and above
The DSW instruction is supported.
"1.014" and above
"1.007H" and above
The UDCNTF instruction is supported.
"1.014" and above
"1.007H" and above
The MTR instruction is supported.
"1.014" and above
"1.007H" and above
The IST instruction is supported.
"1.014" and above
"1.007H" and above
The Step ladder is supported.
"1.014" and above
"1.007H" and above
The predefined protocol support function is
supported.
"1.014" and above
"1.007H" and above
Page 753 SP.ECPRTCL
Page 836 S(P).CPRTCL
The PID instruction is supported.
"1.014" and above
"1.007H" and above
The ESQRT(P) instruction is supported.
"1.015" and above
"1.015R" and above
The number of settable high-speed comparison
tables was changed from maximum 4 to 32.
"1.015" and above
"1.015R" and above
Page 810 HIOEN(P)
Page 813 DHIOEN(P)
The number of high-speed comparisons was
changed from 4 to 32.
"1.015" and above
"1.015R" and above
Page 810 HIOEN(P)
Page 813 DHIOEN(P)
The high-speed pulse input/output module is
supported.
"1.030" and above
"1.025B" and above
Page 612 PWM
Page 618 DPWM
Page 810 HIOEN(P)
Page 813 DHIOEN(P)
Page 816 HCMOV(P)
Page 818 DHCMOV(P)
Page 840 POSITIONING INSTRUCTION
The CC-Link IE field network intelligent device
station is supported.
"1.030" and above
"1.025B" and above
Page 766 NETWORK COMMON
INSTRUCTION
Page 798 CC-LINK IE FIELD NETWORK
INSTRUCTION
The logging instruction is supported
"1.040" and above
"1.030G" and above
Page 732 LOGTRG
Page 733 LOGTRGR
The SLMP frame send instruction is supported
"1.040" and above
"1.030G" and above
The positioning module instruction is supported
"1.050" and above
"1.035M" and above
Page 880 G.ABRSTo
Page 883 GP.PSTRTo
Page 886 GP.TEACHo
Page 889 GP.PFWRT
Page 892 GP.PINIT
Reading/writing data instructions
"1.060" and above
"1.040S" and above
Page 417 S(P).DEVLD
Page 419 SP.DEVST
Extended file register operation instruction
"1.060" and above
"1.040S" and above
Page 422 ERREAD
Page 425 ERWRITE
Page 428 ERINIT
Real-time monitor function instruction
"1.060" and above
"1.040S" and above
Slave station No. (MODBUS address number)
that can be set in FX5 master station was
changed from 32 to 247.
"1.060" and above
"1.040S" and above
Add U
\G
to applicable devices of
BLKMOV(P) instruction.
"1.060" and above
"1.040S" and above
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......