Press the power switch and turn on the
power.
Reinsert the power plug into the power
outlet.
Clean the sensors.
Replace the HEPA filter and the
activated charcoal filter.
Clean the sensors.
Replace the HEPA filter and the
activated charcoal filter.
Clean the Plasma unit.
Reset the intake grill, the HEPA filter
and the activated charcoal filter.
Replace with new batteries, or correctly set
the batteries observing the proper polarity.
12~13
14
14
8
13
8
Symptom
Cause
Remedy
Symptom
Cause
The odor monitor does not change
even when an odor can be noticed
The sensitivity of the sensor differs depending on odor ingredients, and the
monitor display may at times remain unchanged.
●
The following symptoms are not malfunctions.
Should the problem persist after having checked the above list, stop using the unit, remove the power plug and contact
your dealer of purchase or Mitsubishi Electric.
There is no air intake
Odor and smoke are
not completely
removed
Is the fan level lamp on?
(Is the power on?)
Is the power plug securely inserted into
the power outlet?
Are the sensors dusty?
During the Plasma deodorization, you may hear a small hissing noise or notice an ozone smell.
(The level of noise and degree of the smell of ozone will vary depending on the environment.
The generated ozone is of low concentration and is harmless to the body.)
The monitors do not change much
(Odor monitor, microdust monitor and
pollen monitor)
Is the room too large?
Use the unit within the range of the applicable floor area.
Checking monitor operation:
●
Rub tissue paper in front
of the main unit to
discharge dust.
●
Blow cigarette smoke.
If there is a large volume of dust or odor, it may
take some time for the air to become clean.
The monitor lamp flashes
The monitor lamp will flash until the sensors become stable, even if the
power is turned on immediately after inserting the power plug.
The monitor lamp flashes even when
the room is clean
The sensor may at times respond to a breeze from air conditioners within
the room, and gases that are unnoticeable to the human smell.
Is the unit operating in AUTO (NORMAL) mode?
The unit will stop operation when the air is clean.
Are the sensors dusty?
Fan noise and
vibration are louder
than before
Plasma deodorization
lamp flashes
There is an abnormal electrical
discharge.
Is the activated charcoal filter still
wrapped in plastic?
One of the following lamps flash:
FAN/POLLEN GUARD/NORMAL
Are the intake grill, the HEPA filter and
the activated charcoal filter properly set?
The remote controller
does not work
Main unit vibrates
heavily
Little monitor response
Is the unit installed on an unstable or
unlevel surface?
Install on a level and stable surface.
Is the HEPA filter or the activated
charcoal filter dirty?
12~13
Is the HEPA filter or the activated
charcoal filter dirty?
Remove the plastic and replace.
Have the batteries been completely depleted or are
the and of the batteries set correctly?
The air fan does not turn, or there
is no air discharge
A small hissing noise is heard, or there
is a smell of ozone during the Plasma
deodorization
Tr
oub
le-
shooting
15
Maintenance
Troubleshooting
Replacing the filters
T
roub
leshooting