background image

Please replace the HEPA filter and the activated charcoal 
filter with new filters when the color on the surface of the 
HEPA filter matches the color indicated above.

Available from Mitsubishi Electric 

www.plasmapure.com

REPLACE FILTERS

Reset Switch

1

2

3

4

5

6

Reset switch

Beep

14

Use a ball point pen,
or a similar pointed
object, and press
until a beep is heard.

Maintenance (continued)

Replacing the filters

The filter replacement lamp notifies you of the replacement period of the HEPA filter and the activated charcoal filter. 
Replace both the HEPA filter and the activated charcoal filter at the same time.

Replacement period

Color of household dust

Color of cigarette ingredients

The service life of the filters varies depending
on the usage environment, and conditions.

The HEPA filter and the activated charcoal filter
cannot be reused. Always replace old filters
with new filters.

When smoking large amount of cigarettes, odor
may adhere to the filter and main unit. In this
case, clean the main unit, and replace the filters.

Separately sold part:

Replacement filter set

(HEPA filter/activated charcoal filter)

Model

MAPR-E837HFT

Code no. 5D4   C06

To order parts, contact your dealer of purchase

or Mitsubishi Electric @ www.plasmapure.com

Remove the intake grill and the
HEPA filter.

Remove the Plasma unit.

Replace the activated charcoal
filter.

Replace the Plasma unit and
mount a new HEPA filter.

Insert the power plug and press
the Reset Switch.

Set vertically.
(There is no front or back.)

Replace the intake grill.

12~13

Although the replacement period depends on
the usage environment and conditions, the
lamp will light after approximately 5 years
when using the unit on constant MIN fan
speed.
(In the case of MAX, the lamp will light in
approximately 1/4 the time.)

When the filter replacement lamp illuminates

When the HEPA filter becomes dirty and the
color is about the same as that indicated on
the label

Summary of Contents for MA-EF303HS-U

Page 1: ...ote control CONTENTS Page Safety precautions 2 Precautions 4 Names and functions of parts 5 Effective usage 7 Preparations 8 Setting the filters Installing the batteries for remote controller Operation viewing the monitor lamps 9 Changing the airflow 10 Plasma air deodorization 11 Off TIMER operation 11 Monthly cleaning 12 Yearly cleaning 13 Replacing the filters 14 Troubleshooting 15 Specificatio...

Page 2: ...t where the plug cannot be inserted securely Electrical shock short circuit and or fire may occur as a result Do not wash the Plasma unit Using the Plasma unit when wet may cause fire and or electrical shock Do not insert finger or foreign objects into the dust sensor Electrical shock may occur as a result Remove the power plug when cleaning Furthermore never handle the power plug with wet hands o...

Page 3: ...ock fire and or cracking may occur as a result Do not remove the HEPA filter with the unit laying on its back Dust may enter inside the unit and fire and or electrical shock may occur as a result Do not use damaged filters or operate the unit without a filter Contact your dealer or Mitsubishi Electric for a replacement Fire and or electrical shock may occur as a result Do not touch the electric po...

Page 4: ...nit at least 3 3 feet 1m away from televisions cordless telephones air conditioners computers incandescent bulbs fluorescent lighting etc Electrical wave interference may occur resulting in the remote control becoming inoperable Do not use in a location exposed to direct sunlight Deformation and or discoloration may occur as a result Leave space around the unit Walls and or ceiling may become dirt...

Page 5: ...grill On each side of unit Table stand Air fan Spring clips On each side of Plasma unit What is a HEPA filter High Efficiency Particulate Air filter The HEPA filter is a high performance filter than can catch up to 99 97 of all particles as small as 0 3 micron in diameter Handle Exhaust air port Power cord Removing Lay the unit on its back side and then remove the stand by pressing table stand tab...

Page 6: ...ODOR MICRO DUST POLLEN How do the sensors work Odor sensor Using a semiconductor sensor gases from odor ingredients are detected The sensor will react to a breeze from air conditioners fans etc as well as odorless gases and perfumes Dust sensor MICRODUST Using an optical sensor the number of particles less than approximately 1 micron is detected POLLEN Using an optical sensor the number of particl...

Page 7: ... air deodorization switch on the remote only Plasma air deodorization function ON Plasma air deodorization function OFF 9 Operation switch Turns the unit ON Turns the unit OFF Off TIMER switch Switches the timer ON Switches the timer OFF Names and functions of parts Effective usage 10 Use by installing on a high platform Table top POLLEN GUARD operation POLLEN GUARD which reacts to even the slight...

Page 8: ...the activated charcoal filter are titanium oxide not mildew Installing the batteries for the remote controller While pushing the cover slide it forward Insert the batteries Close the cover by sliding it backward until it snaps shut Two AA type batteries Ensure that the proper polarity is observed Use dry cell batteries in a proper manner Do not use rechargeable batteries Make sure that the positiv...

Page 9: ...roller to turn on the air purifier The operation is the same as on the main unit ON OFF Press Press How to use the remote controller The remote controller allows you to operate the unit from a remote place Aim the remote controller toward the main unit and press the switch The maximum range of operation is 23 feet 7 m Remote sensor Remote controller Do not cover the remote sensor with cloths etc I...

Page 10: ... NORMAL Operation switches every time the button is pressed and the selected operation mode lamp lights Operation is automatically adjusted to the appropriate airflow volume according to the odor monitor microdust monitor and pollen monitor POLLEN GUARD The sensor is set to supersensitive to react to even the slightest traces of pollen The fan speed is faster than the NORMAL operation for easier i...

Page 11: ...be heard and the unit may also stop at times If the noise becomes irritating turn off the feature by pressing the PLASMA button on the remote control When the Plasma deodorization lamp is blinking turn the unit off and clean the Plasma unit To operate from the main unit you can turn the Plasma deodorization ON or OFF using the following procedure When the power is turned on press and hold the AUTO...

Page 12: ...ipe with a soft cloth For stubborn dirt wipe with a cloth dampened with water Press the grill release buttons on each side and remove the intake grill Remove the HEPA filter and clean Replace the HEPA filter remove dust by taking care not to tear the HEPA filter surface Do not wash The filter cannot be reused if washed or after becoming wet 8 Replace the intake grill Hook the five tabs on the uppe...

Page 13: ...de remove the intake grill and then remove the HEPA filter Remove the Plasma unit Cleaning the Plasma unit Plasma unit Do not pull by force Malfunction may occur as a result Clean the Plasma unit Lightly flick off the tips Using force may cause the Plasma unit to deform resulting in malfunction of the unit Use a toothbrush and lightly flick off the tips of the electric poles Replace the Plasma uni...

Page 14: ...eplace old filters with new filters When smoking large amount of cigarettes odor may adhere to the filter and main unit In this case clean the main unit and replace the filters Separately sold part Replacement filter set HEPA filter activated charcoal filter Model MAPR E837HFT Code no 5D4 C06 To order parts contact your dealer of purchase or Mitsubishi Electric www plasmapure com Remove the intake...

Page 15: ...pplicable floor area Checking monitor operation Rub tissue paper in front of the main unit to discharge dust Blow cigarette smoke If there is a large volume of dust or odor it may take some time for the air to become clean The monitor lamp flashes The monitor lamp will flash until the sensors become stable even if the power is turned on immediately after inserting the power plug The monitor lamp f...

Page 16: ...HIGH MED LOW MIN MAX HIGH MED LOW MIN 36W 26W 19W 17W 16W 106 CFM 90 CFM 65 CFM 46 CFM 34 CFM 66W 28W 19W 17W 16W 160 CFM 102 CFM 65 CFM 46 CFM 34 CFM MITSUBISHI ELECTRIC AIR PURIFIER MA EF503HS U MA EF303HS U Model Power supply Current fuse 2A motor overheat protection device operational temp 212 F 100 C abnormal electric discharge protection device Remote controller type AA battery 2 MA EF303HS ...

Reviews: