9
Before Use
E
Odor monitor
The state of air contamination
from cigarette odor and other
odors is detected by the odor
sensor and then indicated.
PM2.5 monitor
The state of air contamination from
PM2.5 and other small particles is
detected by the PM2.5 Sensor and then
indicated.
Dust monitor
The state of air contamination from pollen,
dead bodies of mites, and other large
particles is detected by the PM2.5 Sensor
and then indicated.
PM2.5 Sensor
This optical sensor detects the
number of particles.
The monitor indications are divided
into “PM2.5” and “Dust” according
to the size of the particles.
* Particles less than 0.5 μm are not
detected.
Adjusting the Sensitivity of
the PM2.5 Sensor
P.14
l
Operation mode lamps (white)
P.11
Indicate the current operation mode.
l
Power switch
P.11
Turns ON/OFF the power.
l
Auto switch
P.11
Switches the operation mode
between Normal and Night.
l
Manual switch
P.11
Switches the operation mode
between Low, Middle, and High.
l
Operation switch lamps (white)
P.11
Lights when the power switch is turned ON.
Control Panel
l
Clean monitors (orange/red)
The state of air contamination detected with the
odor sensor and PM2.5 Sensor is indicated by
lamps lighting in three steps.
<How to read the clean monitors>
l
Replace Filter lamp (red)
P.17
Lights to notify you when it becomes time to replace
the HEPA filter.
Odor sensor
This semiconducting sensor
detects odors and other gases. It
also responds to wind from air
conditioners, electric fans, and
other appliances, odorless gases,
and perfumes.
Air is
contaminated
Air is clean
Lit in
red
Lit in
orange
Off
l
Reset button
P.17
(The button is located at top right of the unit and
accessible by removing the inlet panel.)
Cancels the Replace Filter lamp.
l
i-see Sensor lamp (green/orange)
l
Lights according to the clean monitors.
(
When clean monitor lamps are lit: Orange
)
When clean monitor lamps are off: Green
l
Flashes in green during the i-see Sensor detection operation.
<Size of dirt particles>
Viruses
Dust, particles harmful to the lungs
Feces and dead bodies of mites
Cigarette smoke particles
PM2.5 monitor
Dust monitor
Pollen
0.01
0.1 0.5
2.5
1
10
100 (μm)
PM2.5
Mainly particles of 2.5 μm or less
Mainly particles greater than 1 μm
ma-e100r-e_cs55.indb 9
2020/08/28 11:28:22
Summary of Contents for MA-E100R-E
Page 40: ...20 Note ma e100r e_cs55 indb 20 2020 08 28 11 28 48 ...
Page 41: ...21 ES Solución de problemas Note ma e100r e_cs55 indb 21 2020 08 28 11 28 48 ...
Page 62: ...20 Nota ma e100r e_cs55 indb 20 2020 08 28 11 29 04 ...
Page 63: ...21 Risoluzione dei problemi IT Nota ma e100r e_cs55 indb 21 2020 08 28 11 29 04 ...