12
Features
Operations
(when Normal Operation Mode is Selected)
The direction to a person’s location is detected by the i-see Sensor. The air inlet and outlet are moved by the AUTO TURN and the optimal air
flow is created by the louvre according to the person’s location.
When operation is started, the i-see Sensor begins detection. The i-see Sensor turns left and right while
the main unit remains facing forward. After completing one left and right movement (takes approx. two
minutes), the i-see Sensor determines the direction to a person’s location.
<When a person is present>
1
The main unit is turned toward the person’s location automatically and then stopped by the
AUTO TURN.
2
The louvre controls the air-flow direction so that air does not blow directly at the person.
3
Contamination is monitored while removing the dust in the area around the person.
4
When contamination in the room is detected by the PM2.5 Sensor and odor sensor, the air
volume is changed automatically.
After approx. 15 minutes, the main unit is turned to face forward and then stopped by the
AUTO TURN.
The i-see Sensor turns left and right again to detect the direction to a person’s location.
l
If more than one person is detected, the AUTO TURN stop position is determined
automatically depending on the number of persons and the direction to the
persons.
<When a person is not present>
1
The louvre controls the air-flow direction so that air is blown over the entire room while the
main unit remains facing forward.
2
Contamination is monitored while removing the dust in the entire room.
3
When contamination in the room is detected by the PM2.5 Sensor and odor sensor, the air
volume is changed automatically.
After approx. three minutes, the i-see Sensor turns left and right again to detect the
direction to a person’s location.
About i-see Sensor, AUTO TURN,
The i-see Sensor turns approx. 150 degrees in the left and right
directions to detect the direction to a person’s location.
The air inlet and outlet are moved by the AUTO TURN which
moves the main unit according to the person’s location.
The optimal air flow is created by the louvre in order to clean the
area around the person.
Air flow is controlled so that air is not
blown directly at a person.
Air is blown over the entire room.
ma-e100r-e_cs55.indb 12
2020/08/28 11:28:26
Summary of Contents for MA-E100R-E
Page 40: ...20 Note ma e100r e_cs55 indb 20 2020 08 28 11 28 48 ...
Page 41: ...21 ES Solución de problemas Note ma e100r e_cs55 indb 21 2020 08 28 11 28 48 ...
Page 62: ...20 Nota ma e100r e_cs55 indb 20 2020 08 28 11 29 04 ...
Page 63: ...21 Risoluzione dei problemi IT Nota ma e100r e_cs55 indb 21 2020 08 28 11 29 04 ...