background image

The Instruction Manual and Usage Sticker are for the customer, and should be handed over together with the unit.

Read this manual thoroughly before beginning installation to ensure the unit is installed safely and correctly.
Local installation standards should be obeyed and installation should be performed by a qualified professional.

Installation Manual

Hand Dryer 

Model

JT-SB116EH-W-CA

Single-phase 120VAC 

0612874HD7001

GB

For dealers and installers

Do not disassemble

Do not use in shower room

Use a single-phase alternating current 120V power supply.
Voltage in excess of 120V+10% may cause mechanical failure, so stay within the rated range.

Using an incorrect power supply may cause fire, electric shock, or malfunction.

Electrical wiring work should be done by a certified professional in conformance with local standards.

Incorrect wiring can cause electric shocks and fire.

Be sure to install a ground-fault circuit interrupter.

Lack of one may cause electric shock.

A means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
This appliance is not intended for use by young children or infirm persons unless they are adequately 
supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.

Do not modify or disassemble more than necessary.

This may cause fire, electric shock, or injury.

Do not install in shower room or other locations with a great deal of humidity in the air, where 
condensation may form on the unit, or where the unit may come in direct contact with water.

This may cause electric shock or malfunction.

Important!
Follow instructions

Safety precautions 

Grounded connection

Be sure the unit is properly grounded.

Lack of a proper ground may cause electric shock during malfunction or short circuit.

WARNING

The following may lead to death or serious 
personal injury if done incorrectly.

CAUTION

The following may lead to injury or damage to 
buildings or their contents if done incorrectly

Do not attempt installation with the power on in the unit (supply mains).

This may cause electrical shock.

Do not remove the heater.

It may cause fire, electric shock or injury.

Do not use at locations where salt damage may occur or where corrosive, neutral or reductive gas 
are present.

Failure to do any of the above may cause fire, electric shock or trouble.

Prohibited

Do not install the unit in places where vandalism might occur. 

Vandalism may cause malfunction.

Install in a location strong enough to support the weight of the unit.

Injury may be cause by the unit falling.

Wear gloves when installing the unit.

Not doing so may cause injury.

Important!
Follow instructions

JT-SB116EH-W-CA-IM_874HD7001-GB    06.12.9  2:13  PM    ページ 2

Summary of Contents for JT-SB116EH-W-CA

Page 1: ...Young children should be supervised to ensure that they do not play with the appliance Do not modify or disassemble more than necessary This may cause fire electric shock or injury Do not install in shower room or other locations with a great deal of humidity in the air where condensation may form on the unit or where the unit may come in direct contact with water This may cause electric shock or ...

Page 2: ...tion panel screws 5x30 self tapping 6 Installation panel 1 Clip 1 Accessories 98 169 Drain tank Heater Unit mm Air filter Power cord hole rear Terminal block Terminal block 247 835 62 152 56 322 260 300 777 222 2 106 Clip mounting screw 1 2 ...

Page 3: ... mm away from any walls as that is where the power switch is located Ensure there are no mirrors or walls near the right side as drops of water may splash when drying hands We recommend a distance of at least 100 mm Avoid locations where people or doors might bump into the unit Choose a completely flat surface on the wall to install the unit If the wall is not concrete reinforce it before installa...

Page 4: ...round wire If no conduit box is installed the power cord could hinder the unit from seating snugly on the wall Power cord with ground wire Approx 400mm Remove the drain tank Do not use socket outlets near water Follow local standards and guidelines Make sure that the power supply is a single phase alternating current 120V Make sure that a ground fault circuit interrupter is installed in the fixed ...

Page 5: ...et in the screw hole 1 2 Remove screws 2 pcs Disengage the front panel at its groove from the unit Then remove the panel Run the power cord through the unit and secure to the installation panel 2 Remove the terminal cover 1 Remove the front panel Remove the terminal cover mounting screw Then pull to remove the cover toward you 3 Groove Front panel mounting screw Front panel Unit Terminal cover mou...

Page 6: ...s install on the unit as it was Confirm that the front panel is fitted securely 1 Install the front panel 5 1 2 3 4 1 2 3 Remove the wire sheath for 15 mm from the end Connect the ground wire using the ground screw provided at the right side of the terminal block and washer Use the washer at the position as illustrated at right Screw tighten the power cord to the terminal block securely Check by p...

Page 7: ... the power switch on Turn on power by using the means for disconnection Is the power lamp in the display on Dry hands Is the air blowing Turn the air speed knob while inserting the hands Turn on the heater switch Does the air speed change Is the heater lamp illuminating at the display Does hot air blow out It takes a few minutes before hot air blows after turning on the switch Burning smell of oil...

Page 8: ...1 3 Komaba cho Nakatsugawa City Gifu Prefecture Japan ...

Reviews: