19
─
Assembly precautions
• Run the heater lead wires as shown in the picture at right.
• Fit the thermal fuse parts into the grooves of the heater fittings.
(Indicated by
)
• Align the cable ties with the edge of the grooves. (Indicated by
)
Blower cover
(7) Blower assembly (Thermal fuse of the motor)
1
Remove the front panel.
→
See (2)
1
and
2
.
2
Disconnect the connectors (CN201 and CN202) from the control
circuit board.
→
See (2)
4
.
3
Disconnect the blower lead connectors (TAB3 and TAB4) from the
power circuit board.
→
See (4)
2
and
3
.
4
Push the cord bush into the blower cover. (Indicated by
)
Assembly precautions
• Attach the cord bush as shown in the picture at right.
• Make sure that there is no slack in the lead wires inside the blower
cover.
Cord bush
5
Unscrew the screw to remove the intake air duct.
(One PTT screw 4 x 14, indicated by
)
Intake air duct
Assembly precaution
Set the intake air duct in the groove of the blower cover. (Indicated
by
)
Tightening torque:
1.0 ± 0.1 N.m