110 mm
or more
100 mm
or more
100 mm
or more
350 mm
or more
100 mm
or more
200 mm
or more
Open two sides of left,
right, or rear side.
1-4. INSTALLATION DIAGRAM
2-1. FIXING OF INSTALLATION PLATE
• Find a structural material (such as a stud) in the wall and fix installation plate (1) hori-
zontally by tightening the fixing screws (2) firmly.
• To prevent installation plate (1) from vibrating, be sure to install the fixing screws in the
holes indicated in the illustration. For added support, fixing screws may also be installed
in other holes.
• When bolts recessed in the concrete wall are to be utilized, secure installation plate (1)
using 11 × 20 · 11 × 26 oval hole (450 mm pitch).
• If the recessed bolt is too long, change it for a shorter one available in the market.
2-2. WALL HOLE DRILLING
1) Determine the wall hole position.
2) Drill a ø65 mm hole. The outdoor side should be 5 to 7
mm lower than the indoor side.
3) Insert wall hole sleeve (C).
2-3. CONNECTING WIRES FOR INDOOR UNIT
You can connect indoor/outdoor lead wire without removing the front panel.
1) Open the front panel.
2) Remove VA clamp.
3) Pass indoor/outdoor unit connecting wire (A) from the back of the indoor unit and process
the end of the wire.
4) Loosen terminal screw, and connect first the earth wire, then indoor/outdoor unit con-
necting wire (A) to the terminal block. Be careful not to make mis-wiring. Fix the wire to
the terminal block securely so that no part of its core is appeared, and no external force
is conveyed to the connecting section of the terminal block.
5) Firmly tighten the terminal screws to prevent them from loosening. After tightening, pull
the wires lightly to confirm that they do not move.
6) Secure indoor/outdoor unit connecting wire (A) and the earth wire with the VA clamp.
Never fail to hook the left claw of the VA clamp. Attach the VA clamp securely.
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1) Installation plate
1
(2)
Installation plate fixing screw
4 × 25 mm
5
(3) Remote controller holder
1
(4)
Fixing screw for (3)
3.5 × 16 mm (Black)
2
(5) Battery (AAA) for (6)
2
(6) Wireless remote controller
1
(7)
Felt tape
(For left or left-rear piping)
1
PARTS TO BE PROVIDED
AT YOUR SITE
(A) Indoor/outdoor unit connecting wire*
1
(B) Extension pipe
1
(C) Wall hole sleeve
1
(D) Wall hole cover
1
(E) Pipe fixing band
2 to 5
(F) Fixing screw for (E) 4 × 20 mm
2 to 5
(G) Piping tape
1
(H) Putty
1
(I)
Drain hose
(or soft PVC hose, 15 mm inner
dia. or hard PVC pipe VP16)
1
(J) Refrigeration oil
1
(K) Power supply cord*
1
Units should be installed by licensed contractor
according to local code requirements.
Liquid pipe
Gas pipe
Felt tape (7)
Indoor/outdoor unit
connecting wire (A)
Piping tape (G)
Indoor unit
Wall hole
sleeve (C)
Cut off the
extra length.
Pipe fixing band
(E)
Be sure to use wall hole
sleeve (C) to prevent in-
door/outdoor connecting
wire (A) from contacting
metal parts in the wall
and to prevent damage by
rodents in case the wall
is hollow.
Wall hole cover (D)
Seal the wall hole
gap with putty (H).
Fix the pipe to wall
with pipe fixing
band (E).
Fixing screw (F)
After the leak test, apply
insulating material tightly so
that there is no gap.
When the piping is to be
attached to a wall containing
metals (tin plated) or metal
netting, use a chemically
treated wooden piece 20 mm
or thicker between the wall
and the piping or wrap 7 to 8
turns of insulation vinyl tape
around the piping.
To use existing piping, per-
form COOL operation for
30 minutes and pump down
before removing the old air
conditioner. Remake flare
according to the dimension
for new refrigerant.
2. INDOOR UNIT INSTALLATION
2-4. PIPE FORMING AND DRAIN PIPING
Pipe Forming
• Place the drain hose below the refrigerant piping.
• Make sure that the drain hose is not heaved or snaked.
• Do not pull the hose when applying the tape.
• When the drain hose passes the room, be sure to wrap
insulation material (obtainable at a store) around it.
* Note:
Place indoor/outdoor unit connecting wire (A) and
power supply cord (K) at least 1 m away from the
TV antenna wire.
Appearance of the outdoor unit may differ from some models.
100 mm or more
Air inlet
Air outlet
Outdoor unit installation
4-10 mm × 16 mm slot
718 mm
70 mm
500 mm
300 mm
255 mm
264-280 mm
40 mm
12 mm
or more
54 mm or
more/ 130 mm
or more for left and
left back piping
(using spacer)
Wall
Outdoor
side
5-7 mm
ø65 mm
Installation plate (1)
Plumb
Align the plumb
line with the
mark
.
Center of
ø65 mm hole
110 mm
or more
100 mm
or more
Bind the line to the center hole.
54 mm or more
130 mm or more for left and left
back piping (using spacer)
Ceiling
Wall
Wall
Fixing screw (2)
* Same for left hole.
Insert
the
scale. *
Align the
scale with
the line. *
100 mm
Level
Terminal block
Fixing screw
Indoor/outdoor unit
connecting wire (A)
VA clamp
Lead wire
15 mm
35 mm
• For future servicing, give extra length to
the connecting wires.
• Make earth wire a little longer than others.
(More than 60 mm)
• Do not fold the excess wire, or cram it into
small space. Take caution not to damage
the wires.
• Be sure to attach each screw to its corre-
spondent terminal when securing the cord
and/or the wire to the terminal block.
Note:
Do not place the wires between the
indoor unit and the installation plate (1).
Damaged wire could cause heat genera-
tion or fire.
Indoor terminal block
Indoor/outdoor
unit connecting
wire (A)
Outdoor terminal block
Earth wire
(green/yellow)
2 N L
2 N L