3 - 18 3 - 18
MELSEC-Q
3 SPECIFICATIONS
Device No.
Signal name
Description
XC
Set value change
completed flag
(1) This is used as an interlock condition for setting Set value change request (YC) to
on/off when adjusting the offset/gain settings.
(2) Refer to Section 4.6 regarding the offset and gain settings.
Performed by the D/A converter module
Performed by the sequence program
XD
Synchronous
output mode flag
This flag turns on when the system is set to the synchronous output mode.
XF Error
flag
(1) Error flag (XF) turns on when a write error occurs.
(2) To turn Error flag (XF) off, remove the cause of the error and set Error clear request
(YF) to on.
Performed by the D/A converter module
Performed by the sequence program
Set value change request (YC)
Set value change completed
flag (XC)
Error flag (XF)
Error clear request (YF)
Error code is read during this interval.