Ladder example
The program switches between manual and automatic operations using the MC and MCR instructions.
Low speed
High speed
3sec.
10sec.
Manual program
Instruction for auto high-speed
Low-speed operation
High-speed operation
Automatic program
• When the manual operation is selected by turning off X7;
1) Turning X2 sets the system to the low-speed operation mod
e.
2) Turning X3 sets the syst
em
to the high-speed operation mode.
• When the automatic operation is selected by turning on X7
.
After X0 is turned on
the system operates in
the low-speed mode for 3sec.
Then the system operates in
the high-speed mode for 10sec. and stops.
X7
MC
N0
M100
N0
M100
X2
M82
M81
X3
M81
M82
MCR
N0
X7
MC
N0
M101
N0
M101
X0
T1
M110
M110
OUT
T1
K30
M110
PLF
M112
M112
T2
M120
M120
OUT
T2
K100
MCR
N0
M81
Y1
M110
M82
Y2
M120
Instruction for manual low-speed
Instruction for manual high-speed
Automatic start
Instruction for auto low-speed
End of
m
anual program
End of a
utomatic program
56