Peripherals for FX5-SSC-G
The following figure shows the peripherals when the FX5-SSC-G is used.
Using the table below, refer to the manual that is appropriate for the input signal to be used.
The Motion module cannot be used together with safety extension modules when the firmware version of the
Motion module is Ver. "1.000". When using with safety extension modules together, connect the Motion
module with the firmware version "1.000" or later. There are restrictions by the version when using together
with the following intelligent function modules other than safety extension modules and the Motion modules.
FX5-20PG-P ("1.011" or later)
FX5-20PG-D ("1.011" or later)
FX5-CCLGN-MS ("1.002" or later)
FX5-DP-M ("1.001" or later)
For details, refer to the following manual.
MELSEC iQ-F FX5U User’s Manual (Hardware)
Input signal
Reference
• External command signal/swtiching signal
• Forced stop input signal
• Manual pulse generator input signal
MELSEC iQ-F FX5 Motion Module/Simple Motion Module User’s Manual (Application)
• Incremental synchronous encoder input signal
MELSEC iQ-F FX5 Motion Module/Simple Motion Module User’s Manual (Advanced
Synchronous Control)
Motion module
Servo
motor
TSN switching hub
Servo
motor
FX5-40SSC-G: Up to 4 Motion control st 16 standard stations
FX5-80SSC-G: Up to 8 Motion control st 16 standard stations
Ethernet
CC-Link IE TSN compatible
servo amplifier
(MR-J5(W)-G servo amplifier)
CC-Link IE TSN compatible
inverter
CC-Link IE TSN compatible
slave modules
Personal computer