Appendix 9 Setting Example for Motion Modules (FX5-SSC-G)
■
Network configuration setting
• Start the network configuration
Double click Navigation window
[Parameter]
[Module Information]
[Target module]
[Module Parameter
(Network)]
[Basic Settings]
[Network Configuration Settings] (or click the button on the right side)
"CC-Link IE
TSN Configuration" screen
• Select and add modules from "Module List" on the "CC-Link IE TSN Configuration" screen.
• A default station No. and I/O point No. are set when a module is added. IP addresses are set automatically in the order in
which the modules were added via drag and drop according to the setting and station No. of the master station.
Drag and drop