MENU
35
3
3.2.4
Parameter copy
(1) Copying parameter settings
Parameter settings of an inverter can be read, and the settings of up to three inverters can be stored in the copy area of the
FR-LU08(-01). The stored parameter settings can be copied to other inverters of same series.
• To read the parameter settings of the inverter and store them to the FR-LU08(-01)
1
Connect the FR-LU08(-01) to the source inverter.
2
Display the Function menu, turn
to move the cursor to
[Parameter copy], and press
.
3
Turn
to move the cursor
to the copy area for parameter
setting storage, and press
.
4
Turn
to move the cursor
to [1: Read VFD], and press
.
(SET)
BACK
S E T
N E X T
Parameter copy
CopyArea1
CopyArea2
CopyArea3
SET
STOP
PU
(SET)
BACK
S E T
N E X T
CopyArea1
1 : Read VFD
2 : Write VFD
3 : Verifying
SET
STOP
PU
(SET)
5
A name (up to 9 letters) can be entered for the selected area.
Turn
to select "0 to 9", "A
to Z", ".", "_", "/" or "(space)".
Press
to move the
cursor. Press
after
completing the input.
6
A confirmation screen appears
for overwriting the selected
area. Press
to execute
the parameter setting storage.
BACK
S E T
N E X T
1 : Read VFD
Name:
ABCDEFGHI
SET
STOP
PU
▲
(→)
(SET)
BACK
S E T
1 : Read VFD
ABCDEFGHI
Overwrite CopyArea 1
SET : Execution
BACK : Cancel
S E T
S E T
S E T
SET
STOP
PU
(SET)
Summary of Contents for FR-LU08