FUNCTION AND BASIC OPERATION
27
2
2.5.2
Selecting the parameter from the Function group menu to change the set value
Example: To change the
F011 Deceleration time
setting from 5 s to 180 s
1
Display the Quick menu and press
. The group
parameter setting mode is activated.
2
Turn
to move the cursor to [F Acc/Dec], and press
.
The setting items are displayed.
3
Turn
to move the cursor to [0 Time setting], and press
. The parameters on time setting are displayed.
(LIST)
P R E V
S E T
N E X T
SET
Pr SET
▼
LIST
Group parameter setting
P
S E T
T
Function group Menu
E Environm.setting
F Acc/Dec
D Opr/Freq command
SET
BACK
STOP
PU
Quick menu
STOP
PU
Easy setup wizard
Pr. list for App.
Simple Pr. list
(SET)
BACK
SET
STOP
PU
F Acc/Dec
0 Time setting
1 Pattern setting
2 Backlash
▼
(SET)
BACK
SET
STOP
PU
▼
F0 Time setting
00 Acc/Dec ref. F
01 Time increments
02 JOG Acc/Dcc time
4
Turn
to move the cursor to [11 Dec. time], and press
. The present set value is displayed.
5
Turn
to set the value to [180.0], and press
. The set
value is changed.
(SET)
BACK
SET
STOP
PU
5.0 sec
5.0 sec
F011 Dec. time
0-3600
Pres value
Set value
NEXT
(SET)
▼
5.0 sec
180.0 sec
Setting is completed
BACK
STOP
PU
F011 Dec. time
Pres value
Set value
NEXT