Parameter List
Parameters
5 - 2
5.1 Parameter
List
5.1.1
Parameter list (by number)
For simple variable-speed operation of the inverter, the initial value of the parameters may be used as
they are. Set the necessary parameters to meet the load and operational specifications. Parameter set-
ting, change and check can be made from the operation panel (FR-DU08).
NOTES
indicates simple mode parameters. Use Pr. 160 "User group read selection" to switch
between the simple mode and extended mode.
Parameter setting may be restricted in some operating statuses. Use Pr. 77 "Parameter write selec-
tion" to change the setting.
Refer to Appendix A.3 (page A-5) for instruction codes for communication and availability of
parameter clear, all clear, and parameter copy of each parameter.
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Basic fu
nc
tio
n
s
0
G000
Torque boost
0 to 30%
0.1%
1
H400
Maximum frequency
0 to 120 Hz
0.01 Hz
120 Hz
60 Hz
2
H401
Minimum frequency
0 to 120 Hz
0.01 Hz
0 Hz
3
G001
Base frequency
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
4
D301
Multi-speed setting (high speed)
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
5
D302
Multi-speed setting (middle speed)
0 to 590 Hz
0.01 Hz
30 Hz
6
D303
Multi-speed setting (low speed)
0 to 590 Hz
0.01 Hz
10 Hz
7
F010
Acceleration time
0 to 3600 s
0.1 s
15 s
8
F011
Deceleration time
0 to 3600 s
0.1 s
9
H000
C103
Electronic thermal O/L relay
Rated motor current
0 to 500 A
0.01 A
Inverter rated
current
0 to 3600 A
0.1 A
Tab. 5-2:
Parameter overview (by number) (1)
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......