456
PARAMETER
*7
These are not available for
.
*8
These are not available for
.
*9
These are not available for
.
*10 These are not available for
.
*11 Increment is 1 when [
Pr. 37
=1 to 9998] or [
Pr. 144
=2 to 10, 102 to 110] in
.(
*12 Data format is in 6 digits (E2) when [
Pr. 37
=0.01 to 9998] and "01" is set to the instruction code HHF in
.
[Fault data]
Refer to page 97 for details of fault description.
A700
F700
E700
D700
A700
F700
E700
D700
Data
Description
Data
Description
Data
Description
H00
No fault
present
H91
*3
E.PTC
HD1
*2*3*4
E.OSD
Fault definition display example (instruction code H74)
H10
E.OC1
HA0
*3*4
E.OPT
HD2
*2*3*4
E.ECT
H11
E.OC2
HA1
*1*4
E.OP1
HD3
*2*3*4
E.OD
H12
E.OC3
HA3
*2*3*4
E.OP3
HD5
*2*3*4
E.MB1
H20
E.OV1
HB0
E.PE
HD6
*2*3*4
E.MB2
H21
E.OV2
HB1
E.PUE
HD7
*2*3*4
E.MB3
H22
E.OV3
HB2
E.RET
HD8
*2*4
E.MB4
H30
E.THT
HB3
*3*4
E.PE2
HD9
*2*4
E.MB5
H31
E.THM
HC0
E.CPU
HDA
*2*4
E.MB6
H40
E.FIN
HC1
*3*4
E.CTE
HDB
*2*4
E.MB7
H50
*3*4
E.IPF
HC2
*3*4
E.P24
HDC
*2*3*4
E.EP
H51
*3*4
E.UVT
HC4
*3
E.CDO
HF1
*4
E. 1
H52
E.ILF
HC5
E.IOH
HF2
*2*3*4
E. 2
H60
E.OLT
HC6
*3*4
E.SER
HF3
*2*3*4
E. 3
H70
E.BE
HC7
E.AIE
HF6
*4
E. 6
H80
E.GF
HC8
*2*4
E.USB
HF7
*3*4
E. 7
H81
E.LF
HC9
*1*2*3
E.SAF
HFB
*2*3*4
E. 11
H90
E.OHT
HD0
*2*3*4
E.OS
HFD
*4
E. 13
*1
These are not available for
.
*2
These are not available for
.
*3
These are not available for
.
*4
These are not available for
.
For read data H30A0
(Previous fault ...... THT)
(Latest fault ...... OPT)
0
1
0
1 0 0 0 0
0
0
0
0
0
0
1
1
b15
b8 b7
b0
Latest fault
(HA0)
Previous fault
(H30)
A700
F700
E700
D700