Position control by vector control
Parameter
6 - 132
The above parameters can be set when the FR-A7AP (option) is mounted.
Pr.
No.
Name
Initial
Value
Setting
Range
Selection Method
(OFF: —, ON:
✔
)
Position feed
frequency
Parameters referred to
Refer to
Section
REX
RH
RM
RL
465
First position feed
amount lower 4 digits)
0
0–9999
—
✔
—
—
High speed
(Pr. 4)
20
29
Acceleration/decel-
eration reference
frequency
Acceleration/decel-
eration pattern
selection
466
First position feed
amount upper 4 digits
0
0–9999
467
Second position feed
amount lower 4 digits
0
0–9999
—
—
✔
—
Middle speed
(Pr. 5)
468
Second position feed
amount upper 4 digits
0
0–9999
469
Third position feed
amount lower 4 digits
0
0–9999
—
—
—
✔
Low speed
(Pr. 6)
470
Third position feed
amount upper 4 digits
0
0–9999
471
Fourth position feed
amount lower 4 digits
0
0–9999
—
—
✔
✔
4. speed
(Pr. 24)
472
Fourth position feed
amount upper 4 digits
0
0–9999
473
Fifth position feed
amount lower 4 digits
0
0–9999
—
✔
—
✔
5. speed
(Pr. 25)
474
Fifth position feed
amount upper 4 digits
0
0–9999
475
Sixth position feed
amount lower 4 digits
0
0–9999
—
✔
✔
—
6. speed
(Pr. 26)
476
Sixth position feed
amount upper 4 digits
0
0–9999
477
Seventh position feed
amount lower 4 digits
0
0–9999
—
✔
✔
✔
7. speed
(Pr. 27)
478
Seventh position feed
amount upper 4 digits
0
0–9999
479
Eighth position feed
amount lower 4 digits
0
0–9999
✔
—
—
—
8. speed
(Pr. 232)
480
Eighth position feed
amount upper 4 digits
0
0–9999
481
Ninth position feed
amount lower 4 digits
0
0–9999
✔
—
—
✔
9. speed
(Pr. 233)
482
Ninth position feed
amount upper 4 digits
0
0–9999
483
Tenth position feed
amount lower 4 digits
0
0–9999
✔
—
✔
—
10. speed
(Pr. 234)
484
Tenth position feed
amount upper 4 digits
0
0–9999
485
Eleventh position feed
amount lower 4 digits
0
0–9999
✔
—
✔
✔
11. speed
(Pr. 235)
486
Eleventh position feed
amount upper 4 digits
0
0–9999
487
Twelfth position feed
amount lower 4 digits
0
0–9999
✔
✔
—
—
12. speed
(Pr. 236)
488
Twelfth position feed
amount upper 4 digits
0
0–9999
489
Thirteenth position feed
amount lower 4 digits
0
0–9999
✔
✔
—
✔
13. speed
(Pr. 237)
490
Thirteenth position feed
amount upper 4 digits
0
0–9999
491
Fourteenth position feed
amount lower 4 digits
0
0–9999
✔
✔
✔
—
14. speed
(Pr. 238)
492
Fourteenth position feed
amount upper 4 digits
0
0–9999
493
Fifteenth position feed
amount lower 4 digits
0
0–9999
✔
✔
✔
✔
15. speed
(Pr. 239)
494
Fifteenth position feed
amount upper 4 digits
0
0–9999
Summary of Contents for FR-A700 EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Page 38: ...Enclosure design Installation 2 14 ...
Page 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Page 820: ...Parameter list with instruction codes Appendix A 50 ...
Page 825: ......