1
en
Contents
1. Safety Notices ..................................................................
2
2. Introduction ......................................................................
3
3. Technical Information ......................................................
4
4. Installation ......................................................................
11
4.1 Location .......................................................................
11
4.2 Water Quality and System Preparation ....................
13
4.3 Water Pipe Work .........................................................
14
4.4 Electrical Connection ................................................
16
5. System Set UP ................................................................
18
5.1 DIP Switch Functions ................................................
18
5.2 Connecting inputs/outputs .......................................
19
5.3 Wiring for 2-zone temperature control ....................
20
5.4 Indoor unit only operation (during installation work) ...
21
5.5 Using SD memory card.............................................. 21
5.6 Main remote controller............................................... 22
6. Service and Maintenance ..............................................
29
Abbreviations and glossary
No. Abbreviations/Word
Description
1 Compensation curve mode
Space heating incorporating outdoor ambient temperature compensation
2 COP
Coefficient of Performance the efficiency of the heat pump
3 Cooling mode
Space cooling through fan-coils or underfloor cooling
4 DHW mode
Domestic hot water heating mode for showers, sinks, etc
5 Flow temperature
Temperature at which water is delivered to the primary circuit
6 Freeze stat. function
Heating control routine to prevent water pipes freezing
7 FTC
Flow temperature controller, the circuit board in charge of controlling the system
8 Heating mode
Space heating through radiators or Underfloor heating
9
Hydrobox
Indoor unit housing the component plumbing parts (NO DHW tank)
10 Legionella
Bacteria potentially found in plumbing, showers and water tanks that may cause Legionnaires disease
11 LP mode
Legionella prevention mode – a function on systems with water tanks to prevent the growth of legionella bacteria
12 Packaged model
Plate heat exchanger (Refrigerant - Water) in the outdoor heat pump unit
13
PRV
Pressure relief valve
14
Return temperature
Temperature at which water is delivered from the primary circuit
15 Split model
Plate heat exchanger (Refrigerant - Water) in the indoor unit
16
TRV
Thermostatic radiator valve – a valve on the entrance or exit of the radiator panel to control the heat output
For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the
hydrobox unit.
English is the original language. The other language versions are translations of the original.
If you want more information that is not written in this manual, go to the
above website to download manuals, select model name, then choose
language.
http://www.mitsubishielectric.com/ldg/ibim/
Contents of website manual
•
Energy monitor
•
Room thermostat
•
Filling the system
•
Simple 2 zone system
•
Independent electrical power source
•
Smart grid ready
•
DHW tank for Hydrobox
•
Remote controller options
•
Service menu (special setting)
•
Supplementary information
Accessories (included)
Back plate
Screw M5×8
SD memory card
Joint pipe*
1
2
1
1
* Only E*SE series