11
5.1. Checking the contents (Fig. 5-1)
• This kit contains this manual and the following parts.
Accessory name
Q’ty
Remark
1
Grille
1
950 × 950 (mm)
2
Screw with captive washer
4
M5 × 0.8 × 25
3
Gauge
1
(Divided into four parts)
4
Fastener 3
5
Screw
4
4 × 8
6
Screw
1
4 × 12
7
i-see sensor corner panel
1
for PLP-6BAE
5.2. Preparing to attach the grille (Fig. 5-2)
• With the gauge
3
supplied with this kit, adjust and check the positioning of the
unit relative to the ceiling. If the unit is not properly positioned relative to the ceil-
ing, it may allow air leaks or cause condensation to collect.
• Make sure that the opening in the ceiling is within the following tolerances:
860 × 860 - 910 × 910
• Make sure that A is performed within 17-22 mm. Damage could result by failing
to adhere to this range.
A
Main unit
B
Ceiling
C
Gauge
3
(inserted into the unit)
D
Ceiling opening dimensions
5.2.1. Removing the intake grille (Fig. 5-3)
• Slide the levers in the direction indicated by the arrow
1
to open the intake grille.
• Unlatch the hook that secures the grille.
* Do not unlatch the hook for the intake grille.
• With the intake grille in the “open” position, remove the hinge of the intake grille
from the grille as indicated by the arrow
2
.
5.2.2. Removing the corner panel (Fig. 5-4)
• Remove the screw from the corner of the corner panel. Slide the corner panel as
indicated by the arrow
1
to remove the corner panel.
[Fig.5-3, 5-4]
A
Intake
grille
B
Grille
C
Intake grille levers
D
Grille
hook
E
Hole for the grille’s hook
F
Corner
panel
G
Screw
H
Detail
5.3. Selection of the air outlets
For this grille the discharge direction is available in 11 patterns. Also, by setting the
remote controller to the appropriate settings, you can adjust the airfl ow and speed.
Select the required settings from the Table 1 according to the location in which you
want to install the unit.
1) Decide on the discharge direction pattern.
2) Be sure to set the remote contoller to the appropriate settings, according to the
number of air outlets and the height of the ceiling on which the unit will be in-
stalled.
Note:
For 3 and 2-directional, please use the air outlet shutter plate (option).
5.4. Installing the grille
5.4.1. Preparations (Fig. 5-5)
• Install the 2 enclosed screws with washer
2
in the main unit (at the corner drain
pipe area and at the opposite corner) as shown in the diagram.
5. Installing the grille
Fig. 5-5
15-20
4-directional
3-directional
1 pattern:
4 patterns:
Initial setting
1 air outlet fully closed
2-directional
6 patterns:
2 air outlet fully closed
Blowout
direction
patterns
Blowout
direction
patterns
Fig. 5-1
Fig. 5-2
A=17
+5 0
Fig. 5-3
Fig. 5-4
Main unit
Screw with captive washer
20
Table 1