14
OCH610G
Service Ref.
PLFY-EP36NEMU-E
PLFY-EP48NEMU-E
Power source
1-Phase 208–230 V, 60 HZ
Cooling capacity
(Nominal)
*1
*1
Btu/h
36,000
10.5
48,000
14.1
kW
Power input
kW
0.07
0.11
Current input
A
0.73
1.01
Heating capacity
(Nominal)
*2
*2
Btu/h
40,000
11.7
54,000
15.8
kW
Power input
kW
0.07
0.11
Current input
A
0.68
0.96
([WHUQDO¿QLVK
Galvanized steel sheet
External dimension H × W × D
in
11-3/4 × 33-3/32 × 33-3/32
298 × 840 × 840
11-3/4 × 33-3/32 × 33-3/32
298 × 840 × 840
mm
Net weight
lbs [kg]
55 [25]
55 [25]
Grille
Model
PLP-40EAEU
PLP-40EAEU
([WHUQDO¿QLVK
MUNSELL (6.4Y 8.9/0.4)
Dimension
H × W × D
in
1-9/16 × 37-13/32 × 37-13/32
40 × 950 × 950
1-9/16 × 37-13/32 × 37-13/32
40 × 950 × 950
mm
Net weight
lbs [kg]
11 [5]
11 [5]
Heat exchanger
&URVV¿Q
FAN
Type × Quantity
Turbo fan × 1
Turbo fan × 1
External static
press.
in. WG
0.000 (208 V)
0
0.000 (208 V)
0
Pa
in. WG
0.000 (230 V)
0
0.000 (230 V)
0
Pa
Motor type
DC motor
Motor output
kW
0.120
0.120
Driving mechanism
Direct drive
$LUÀRZUDWH
(Low-Mid2-
Mid1-High)
cfm
777-883-989-1,095
22.0-25.0-28.0-31.0
367-417-467-517
777-953-1,059-1,236
22.0-27.0-31.0-35.0
367-450-517-584
m³/min
L/s
Sound pressure level
(Low-Mid2-Mid1-High)
(measure in anechoic room)
dB <A>
35-37-39-41 (208–230 V)
ʊ
ʊ
36-39-42-45 (208–230 V)
ʊ
ʊ
dB <A>
dB <A>
Insulation material
PS
$LU¿OWHU
33KRQH\FRPEORQJOLIH¿OWHUDQWLEDFWHULDOW\SH
Protection device
Fuse
Refrigerant control device
LEV
Connectable outdoor unit
R410, CITY MULTI
Diameter of refrigerant
pipe (O.D.)
Liquid
in [mm]
3/8 [9.52] Flare
3/8 [9.52] Flare
Gas
in [mm]
5/8 [15.88] Flare
5/8 [15.88] Flare
Field drain pipe size
in [mm]
O.D 1-1/4 [32]
O.D 1-1/4 [32]
Standard attachment
Document, accessory
Installation Manual, Instruction Book
Optional parts
Air outlet shutter plate
PAC-SJ37SP-E
PAC-SJ37SP-E
+LJKHI¿FLHQF\¿OWHUHOHPHQW
PAC-SH59KF-E
PAC-SH59KF-E
Multi-function casement
PAC-SJ41TM-E
PAC-SJ41TM-E
Remarks
Installation
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items
shall be referred to the Installation Manual.
*1
Nominal cooling conditions
*2
Nominal heating conditions
Indoor: 80°F D.B./67°F W.B 70°F D.B.
[26.7°C D.B./19.4°C W.B ] [21.1°C D.B.]
Outdoor: 95°F D.B. 47°F D.B./43°F W.B
[35°C D.B.] [8.3°C D.B./6.1°C W.B]
Pipe length: 25 ft [7.6m] 25 ft [7.6m]
Level difference: 0 ft [0 m] 0 ft [0 m]
1RWH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH
Unit converter
kcal/h = kW × 860
Btu/h = kW × 3,412
cfm = m3/min x 35.31
lb = kg/0.4536
$ERYHVSHFL¿FDWLRQGDWDLV
subject to rounding variation.