9
2SHUDWLRQ)RU:LUHG5HPRWHFRQWUROOHU
Note: “0” indicates all outlets.
+RUL]RQWDODLUÀRZ
Downward
Outlet No. 2
Outlet No. 3
Outlet No. 1
Outlet No. 4
MITSUBISHI
ELECTRIC
label
Remote controller setting
7KHDLUÀRZGLUHFWLRQRIWKLVRXWOHW
LVFRQWUROOHGE\WKHDLUÀRZGLUHF
-
tion setting of remote controller.
Fixed
7KHDLUÀRZGLUHFWLRQRIWKLVRXWOHWLV¿[HG
in particular direction.
* When it is cold because of direct air-
ÀRZWKHDLUÀRZGLUHFWLRQFDQEH¿[HG
KRUL]RQWDOO\WRDYRLGGLUHFWDLUÀRZ
+RZWRVHWWKH¿[HGXSGRZQDLUGLUHFWLRQ2QO\IRU
ZLUHGUHPRWHFRQWUROOHU!
Note:
Ɣ
This function cannot be set depending on the outdoor unit to be
connected.
•
)RU3/)<1(08VHULHVRQO\WKHSDUWLFXODURXWOHWFDQEH¿[HGWR
FHUWDLQGLUHFWLRQZLWKWKHSURFHGXUHVEHORZ2QFH¿[HGRQO\WKHVHW
RXWOHWLV¿[HGHYHU\WLPHDLUFRQGLWLRQHULVWXUQHGRQ2WKHURXWOHWV
follow UP/DOWN air direction setting of remote controller.)
Ŷ
Explanation of word
• “Refrigerant address No.” and “Unit No.” are the numbers given to
each air conditioner.
• “Outlet No.” is the number given to each outlet of air conditioner.
(Refer to the illustration below.)
•
³8S'RZQDLUGLUHFWLRQ´LVWKHGLUHFWLRQDQJOHWR¿[
1
2
3
4
5
Reset
horizontal
Notes:
Ɣ
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Ɣ
Available directions depend on the type of unit connected.
Ɣ
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in “STAND BY” or “DEFROST” states.
,PPHGLDWHO\DIWHUVWDUWLQJKHDWPRGHZKLOHWKHV\VWHPLVZDLW
-
LQJIRUWKHPRGHFKDQJHWRWDNHHIIHFW
3. In heat mode, when room temperature is higher than the tem-
perature setting.
9HQWLODWLRQVHWWLQJ!
Fri
Low
Vent.
MENU
ON
OFF
RETURN SELECT
HOLD
5HWXUQLQJWRWKH2SHUDWLRQPHQX!
MENU
ON
OFF
RETURN SELECT
HOLD
Main menu: RETURN
Cursor
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Press the [F3] button to go through
the ventilation setting options in the
order of “Off ”, “Low”, and “High”.
* Settable only when Lossnay unit is
connected.
Off
Low
High
Off
Low
High
• The fan on some models of indoor
units may be interlocked with certain
models of ventilation units.
Press the [RETURN] button to go
back to the Operation menu.
Summary of Contents for CITY MULTI PLFY-EP.NEMU-E Series
Page 59: ......