PEFY-P72·96NMHU-E-F
11
()
()
S(SHIELD)
PARTS
LOCATION
LEV
adapter
board
INSIDE
SECTION
OF
CONTROL
BOX
2
1
1
2
2
1
AC250V 6.3A
T
AC250V 5A
F
CN27
CN25
CN24
CN23
5
FAN2
1
3
51F
CN82
CN62
SW4
SW2
SW3
CN32
CN52
CN51
CN41
LED2
LED1
SW5
SENSOR
TH24
21
CN22
SW7
1
3
CN3A
1
2
M1
M2
S.B.
DSA1
CN1
1
3
ZNR1
SW14
(Connection
No.)
SW11
(1st
digit)
SW12
(2nd
digit)
F2
F1
1
2
3
4
5
6
LEV2
1
2
3
4
5
6
1
2
3
4
5
6
654321
LEV1
654321
T
A
52F
9
8
6
5
4
321
1
49F
3
2
8
ZNR
XO6
XO5
XO4
4
9
59
7
REMOTE
1
3
CN42
4
3
2
1
4
3
2
1
7 8
TH23
21
CN29
8 7
1
2
3
4
5
6
A.B.
CN3T
3
1
TH22
DS
MF
DP
L1
6
2
5
1
6
4
CN31
3
3
1
3
3
2
2
2
8
5
1
3
1
1
1
1
1
6
5
4
3
2
1
CN81
CN20
CN21
CN31
CN60
CNT
CND
CNP
FAN3
XO1
CN2M
I.B.
1
2
CR
L2 L3
G
52F
6
5
51F
SW1
A.B.
S.B.
TB2
CONTROL
BOX
52F
51F
TB5,TB15
I.B.
Color/External
static
pressure
White/High Blue/Low
TB15
TB5
]
TB2
1 2
3 4 5 6
78
0
8 7 6
5
4
3
2
1
0
9
9A
B
C
DE
F
1
9
0
2 3 4
6
5
7
8
(5
A)
Varistor
ZNR,ZNR1
Connector
CN27
Connector
CN25
Connector
CN24
Connector
CN23
NAME
SYMBOL
Connector
(Centrally
control)
Connector
(HA
terminal-A)
Connector
(Centrally
control)
Connector
(Remote
indication)
CN52
CN51
CN41
CN32
Power
supply
(Remote
controller)
Power
supply
(I.B.)
LED2
LED1
SW5(A.B.)
Thermistor
(Outdoor
air
temp.detection)
TH24
TH23
Transmission
terminal
bed
TB15
Inside
<
>
is
the
optional
parts.
X01,X04
X06
TH22
NAME
SYMBOL
Switch
(1st
digit
address
set)
SW2(I.B.) SW3(I.B.)
SW11(A.B.) SW12(A.B.) SW14(A.B.) SW1(A.B.)
SW7(A.B.)
SW4(I.B.)
Drain
pump
Drain
sensor
Surge
absorber
board
S.B.
Fuse
AC250V
5A
F
Fuse
AC250V
6.3A
T
F1
<DP>
<DS>
SYMBOL
MF I.B. A.B.
T
LEV1,LEV2
Fan
motor
Electronic
linear
expan.
valve
Indoor
controller
board
Address
board
Transformer
TB2 TB5
Transmission
terminal
bed
Power
source
terminal
bed
SYMBOL
EXPLANATION
NAME
<F2>
51F
Inner
thermostat
49F
Over
current
relay
(fan
motor)
Contactor
(fan
motor)
52F
NOTE;1.The
part
of
the
broken
line
indicates
the
circuit
for
optional
parts.
2.
A
in
the
chart
is
the
connector
for
a
drain
pump
test
run
operation.
(The
Drain
Pump
operates
continuously
if
the
connector
is
inserted
and
the
power
is
supplied.)
After
the
test
run,
make
sure
to
remove
the
A
connector.
3.The
wirings
to
TB2,TB5,TB15
shown
in
chained
line
are
field
work.
4.Mark
indicates
terminal
bed,
connector,
board
insertion
connector
or
fastening
connector
of
control
board.
CAUTION;1.To
protect
Fan
motor
from
abnormal
current,
Over
current
relays<51F>
is
installed.
Therefore,
do
not
change
factory
set
value
of
Over
current
relays.
Switch(for
voltage
selection)
TO
MA
REMOTE
CONTROLLER
TO
OUTDOOR
UNIT
BC
CONTROLLER
REMOTE
CONTROLLER
TO
DUCT
POWER
SUPPLY
3
208V/230V
60Hz
Aux.relay
Thermistor
(Piping
temp.detection/gas)
Switch(for
mode
selection)
Switch(for
capacity
code)
Switch
(2nd
digit
address
set)
Switch
(connection
No.set)
Switch(for
mode
selection)
Switch(for
model
selection)
Switch(for
model
selection)
BREAKER
Thermistor
(Piping
temp.detection/liquid)
NOTE
1
A
connector
is
attached
to
the
drain
lift
up
mechanism, which
is
an
optional
part.
NOTE
1,2
NOTE
1
(Red)
(Green)
(Yellow)
(White)
(Yellow)
(Yellow)
(White)
(White)
(Blue)
(Blue)
(White)
(Blue)
(Red)
(White)
(Red)
(Green)
(White)
(White)
(Black)
(White)
(Red)
(Red)
(Red)
(White)
(White)
(Green)
(White)
(White)
(Blue)
(TRANSMISSION
TERMINAL
BED)
(TRANSMISSION
TERMINAL
BED)
Pressure Pressure