WIRING DIAGRAM
PEFY-P40·50·63·71·80·100·125·140VMH-E
Switch(for voltage selection)
attachment to alter the external static pressure on the fan
PE
*NOTE 1,2
*NOTE 1
*NOTE 1
*A
connector is attached to the drain lift up mechanism, which is an optional part.
TO OUTDOOR UNIT
TO MA REMOTE CONTROLLER
BC CONTROLLER REMOTE CONTROLLER
BREAKER(16A)
FUSE(16A)
PULL
BOX
TO NEXT
INDOOR UNIT
TO DUCT
POWER SUPPL
Y
~
220,230,240V
50,60Hz
Switch(for model selection)
Switch(for mode selection)
Switch (connection No.set)
Switch (2nd digit address set)
Switch(for capacity code)
Switch(for mode selection)
*B Capacitor
MODELS 40/50 3.0
µ
F
MODEL
63 4.0
µ
F
MODELS 71/80 5.0
µ
F
MODELS 100/125/140 7.0
µ
F
Thermistor (piping temp.detection/gas)
Thermistor (piping temp.detection/liquid)
Aux.relay
*insert
SW5(A.B)
NOTE;1.The part of the broken line indicates the circuit
for optional parts. 2.*A
in the chart is the connector for a drain pump
test run operation. (The Drain Pump operates continuously if the connector is inserted and the power is supplied.)
After the test run, make sure to remove the
*A
connector
.
3.The wirings to
TB2,TB5 (shown in dotted line) are
field work. 4.Mark indicates terminal bed, connector
, board
insertion connector or fastening connector of control board.
inside < > is the optional parts.
NAME
SYMBOL
EXPLANA
TION
Power source terminal bed T
ransmission terminal bed
TB5
Transmission terminal bed
TB15
TB2
SW4(I.B)
SW1(A.B)
SW14(A.B)
SW12(A.B)
SW1
1(A.B)
SW3(I.B)
SW2(I.B)
Switch (1st digit address set)
T
ransformer
Address board
Indoor controller board
Electronic linear expan. valve
*B Capacitor (for MF)
Fan motor
LEV
T
A.B
I.B
C
MF
SYMBOL
<DS>
<DP>
SYMBOL
NAME
TH22
TH23
Thermistor (inlet temp.detection)
TH21
X04
~
X06
<F2>
F1
Fuse
AC250V 6.3A
F
Fuse
AC250V 5A
F
S.B
Surge absorber board
Drain sensor
Drain Pump
Color/External Static Pressure Red/200Pa (at 220,230,240V) Blue/50Pa (at 220V),100Pa(at 230,240V) White/100Pa (at 220V),150Pa(at 230,240V)
C
TB2
1 2
3 4 5 6
78
0
8 7
6
5
4
3
2
1
0
9
9A
B
C
DE
F
1
9
0
2 3 4
6
5
7
8
TB5(TRANSMISSION TERMINAL
BED)
TB15(TRANSMISSION TERMINAL
BED)
56
SW5
T
ZNR
CN82
CN62
(Blue)
SW4
CN42
4
3
2
1
4
3
21
7 8
TH23
2
1
CN29
8 7
1
2
3
4
5
6
A.B
CN3T
3
1
M1
M2
SW1
SW2
SW3
TH22
TH21
DS
MF
LEV
N
L
6
2
5
17
8
8
9
4
CN31
Drain sensor
31
3
3
1
1
3
2
2
2
4
4
3
3
1
1
1
3
3
1
1
1
1
6
5
4
3
2
1
CN81
CN20
CN21
CN31
CN60
CNT
CND
CNP
FAN3
X01
X05
X06
X04
CN2M
I.B
1
2
1
2
CN3A
1
3
*B
(Red)
3
98
1
98
63
1
9
(White)
56
44
8
8
9
9
5
31
31
DP
1
2
*A
S.B
DSA1
CN1
1
3
ZNR1
SW14 (Connection No.)
SW1
1
(1st digit)
SW12 (2nd digit)
AC250V 5A
F
AC250V 6.3A
F
F1
F2
2
11
2
INSIDE SECTION OF CONTROL
BOX
S(SHIELD)
PE