III
Specifications ]
- 5 -
HWE20150
GB
III
Specifications
[1] Specifications
1. Specifications
Model
PEFY-P06NMAU-E4
PEFY-P08NMAU-E4
PEFY-P12NMAU-E4
PEFY-P15NMAU-E4
Power source
1-phase 208/230V 60Hz
Cooling capacity
*1 BTU / h
6,000
8,000
12,000
15,000
(Nominal)
*1 kW 1.8
2.3
3.5
4.4
Power input
kW
0.042
0.042
0.052
0.062
Current input
A
0.42/0.38
0.42/0.38
0.56/0.51
0.64/0.58
Heating capacity
*2 BTU / h
6,700
9,000
13,500
17,000
(Nominal)
*2 kW 2.0
2.6
4.0
5.0
Power input
kW
0.040
0.040
0.050
0.060
Current input
A
0.42/0.38
0.42/0.38
0.56/0.51
0.64/0.58
External finish
Galvanized steel plate
External dimension H x W x D
in.
9-7/8x27-9/16x28-7/8
9-7/8x27-9/16x28-7/8
9-7/8x27-9/16x28-7/8
9-7/8x35-7/16x28-7/8
mm
250 x 700 x 732
250 x 700 x 732
250 x 700 x 732
250 x 900 x 732
Net weight
lbs (kg)
47(21)
47(21)
47(21)
58(26)
Heat exchanger
Cross fin (Aluminium fin and copper tube)
FAN
Type x Quantity
Sirocco fan x 1
Sirocco fan x 1
Sirocco fan x 1
Sirocco fan x 2
External
in.WG
<0.14>-0.20-<0.28>-<0.40>-<0.60>
static press.
Pa
<35>-50-<70>-<100>-<150>
Motor type
DC motor
Motor
output
kW
0.085 0.085 0.085 0.121
Driving mechanism
Direct-driven by motor
Airflow rate
cfm
212-265-300
212-265-300
265-318-371
353-424-494
(Low-Mid-High)
m
3
/ min
6.0-7.5-8.5
6.0-7.5-8.5
7.5-9.0-10.5
10.0-12.0-14.0
L / s
100-125-142
100-125-142
125-150-175
167-200-233
Sound pressure level
dB <A>
24-28-30
24-28-30
26-30-34
27-31-34
(Low-Mid-High)
(measured in anechoic room)
Insulation material
EPS, Polyethylene foam,Urethane foam
Air filter
PP honeycomb fabric
Protection device
Fuse
Refrigerant control device
LEV
Connectable outdoor unit
R410A CITY MULTI
Diameter of
Liquid
(R410A) in. (mm)
1/4 (6.35) Brazed
1/4 (6.35) Brazed
1/4 (6.35) Brazed
1/4 (6.35) Brazed
refrigerant
pipe
Gas
(R410A) in. (mm)
1/2 (12.7) Brazed
1/2 (12.7) Brazed
1/2 (12.7) Brazed
1/2 (12.7) Brazed
(O.D.)
Diameter of drain pipe
in. (mm)
O.D. 1-1/4(32)
Drawing
External
-
Wiring
-
Refrigerant cycle
-
Standard
Document
Installation Manual, Instruction Book
attachment
Accessory
Washer, Drain hose, Tie band
Optional
External heater adapter
PAC-YU25HT
parts
Filter box
PAC-KE91TB-E
PAC-KE91TB-E
PAC-KE91TB-E
PAC-KE92TB-E
Remark
Installation
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other
items shall be referred to the Installation Manual.
Due to continuing improvement, above specifications may be subject to change without notice.
Note :
*1 Nominal cooling conditions
*2 Nominal heating conditions Unit
convertor
Indoor : 80degF D.B. / 67degF W.B.
70degF D.B.
kcal/h = kW x 860
(26.7degC D.B. / 19.4degC W.B.)
(21.1degC D.B.)
BTU/h = kW x 3,412
Outdoor : 95degF D.B.
47degF D.B. / 43degF W.B.
cfm = m
3
/min x 35.31
(35degC D.B.)
(8.3degC D.B. / 6.1degC W.B.)
lbs = kg / 0.4536
Pipe length : 25 ft. (7.6 m)
25 ft. (7.6 m)
Level difference : 0 ft. (0 m)
0 ft. (0 m)
*Above specification data is
*The external static pressure is set to 0.20in. WG(50Pa) at factory shipment.
subject to rounding variation.
*Due to continuing improvement, above specification may be subject to change without notice.