8
GB
5.5. Airflow up/down direction setting
<To change the airflow up/down direction>
With the unit running, press the Airflow up/down button
6
as
necessary.
• Each press changes the direction. The current direction is shown at
6
.
• The change sequence, and the available settings, are as follows.
Airflow
Display
4 steps
model
Swing
1 2 3 4
5 steps
model*1
Swing
Auto
1
2
3
4
5
* Note that during swing operation, the directional indication on the
screen does not change in sync with the directional vanes on the
unit.
* Some models do not support directional settings.
*1. For MA remote controller only, other remote controllers display the
same as 4 steps model.
*2. Airflow direction setting <Auto>
COOL/FAN/DRY : Setting 1 (Horizontal),
HEAT : Setting 5 (Downward 5)
Note:
Available directions depend on the type of unit connected. Note also that
some units do not provide an “Auto” setting.
In the following cases, the actual air direction will differ from the direction
indicated on the remote controller display.
1. While the display is showing “STAND BY” or “DEFROST”.
2. Immediately after starting heater mode (while the system is waiting for
the operation mode change to take effect).
3. In heat mode, when room temperature is higher than the temperature
setting.
<[Manual] To Change the Airflow’s Left/Right Direction>
* The louver button
7
cannot be used.
Model PKFY-P·VKM-E
• Stop the unit operation, hold the lever of the louver,
and adjust to the desired direction.
* Do not set to the inside direction when the unit is in
the cooling or drying mode because there is a risk of
condensation and water dripping.
Caution:
To prevent falls, maintain a stable footing when operating the unit.
5.6. Ventilation
For LOSSNAY combination
5.6.1. For Wired Remote-controller
To run the ventilator together with the indoor unit:
Press the ON/OFF button
1
.
• The Vent indication appears on the screen (at
8
). The ventilator
will now automatically operate whenever the indoor unit is running.
To run the ventilator only when the indoor unit is off:
Press the Ventilation button
8
while the indoor unit is off.
• The On lamp (at
1
) and the Vent indication (at
8
) come on.
To change the ventilator force:
Press the Ventilation button
8
as necessary.
• Each press toggles the setting, as shown below.
Note:
With some model configurations, the fan on the indoor unit may come on
even when you set the ventilator to run independently.
5. Operation
(Low)
(High)
No display
(Stop)
(OFF)