Example 2:
Start the timer, with OFF time is sooner than ON time
ON Setting: 5 hours
OFF Setting: 2 hours
6.1.3. Auto Off Timer
This timer begins countdown when the air conditioner starts, and
shuts the air conditioner off when the set time has elapsed.
Available settings run from 30 minutes to 4 hours, in 30-minute
intervals.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same
time.
*2. The Auto Off timer will not operate when any of the following conditions
is in effect.
The timer is off; the system is in malfunction state; a test run is in
progress; the remote controller is undergoing self-check or remote
controller check; the user is in the process of selecting a function; the
user is in the process of setting the timer; the system is under central
control. (Under these conditions, On/Off operation is prohibited.)
<How to Set the Auto Off Timer>
1. Be sure that you are at a standard control screen, and that the Auto
Off timer indicator is visible in the display (at
1
).
When something other than the Auto Off Timer is displayed, set it to
AUTO OFF TIMER using the function selection of remote controller
(see 8.[4]–3 (3)) timer function setting.
2. Hold down the Timer Menu button
2
for
3 seconds
, so that the “Set
Up” appears on the screen (at
2
).
(Note that each press of the button toggles the display between “Set
Up” and “Monitor”.)
3. Press the appropriate Set Time button
1
as necessary to set the OFF
time (at
3
).
4. Press the Filter button
4
to lock in the setting.
Note:
Your entry will be cancelled if you press the Operation mode (Back) button
2
before pressing the Filter button
4
.
5. Press the Operation mode (Back) button
2
to complete the setting
procedure and return to the standard control screen.
6. If the air conditioner is already running, the timer starts countdown
immediately.
Be sure to check that the timer setting appears
correctly on the display.
7. After completing steps 3 to 6 above, press the Filter button
4
to
lock in the value.
Note:
Your new settings will be cancelled if you press the Operation mode (Back)
button
2
before pressing the Filter button
4
.
8. Press the Operation mode (Back) button
2
to return to the standard
control screen.
9. Press the Timer On/Off button
9
to start the timer countdown. When
the timer is running, the timer value is visible on the display.
Be sure
that the timer value is visible and appropriate.
<Viewing the Current Simple Timer Settings>
1. Be sure that the simple timer indicator is visible on the screen (at
1
).
2. Press the Timer Menu button
2
, so that the “Monitor” appears on the
screen (at
5
).
• If the ON or OFF simple timer is running, the current timer value will
appear at
6
.
• If ON and OFF values have both been set, the two values appear
alternately.
3. Press the Operation mode (Back) button
2
to close the monitor
display and return to the standard control screen.
<To Turn Off the Simple Timer>
Press the Timer On/Off button
9
so that the timer setting no longer
appears on the screen (at
7
).
<To Turn On the Simple Timer>
Press the Timer On/Off button
9
so that the timer setting becomes
visible at
7
.
Examples
If ON and OFF times have both been set at the simple timer, operation
and display are as indicated below.
Example 1:
Start the timer, with ON time set sooner than OFF time
ON Setting: 3 hours
OFF Setting: 7 hours
TIMER
ON
OFF
Hr
AFTER
SIMPLE
1
6
5
Timer Setting
°C
°C
SIMPLE
7
°C
°C
ON
Hr
AFTER
SIMPLE
7
6. Timer
ON
Hr
AFTER
SIMPLE
°C
°C
OFF
Hr
AFTER
SIMPLE
SIMPLE
At 3 hours after timer start
Display changes to show the timer’s OFF
setting (hours remaining to OFF).
The time displayed is OFF setting (7 hours)
– ON setting (3 hours) = 4 hours.
At Timer Start
Display shows the timer’s ON setting (hours
remaining to ON).
At 7 hours after timer start
The air conditioner goes off, and will remain
off until someone restarts it.
°C
°C
OFF
Hr
AFTER
SIMPLE
ON
Hr
AFTER
SIMPLE
°C
°C
SIMPLE
At 2 hours after timer start
Display changes to show the timer’s ON
setting (hours remaining to ON).
The time displayed is ON setting (5 hours)
– OFF setting (2 hours) = 3 hours.
At Timer Start
Display shows the timer’s OFF setting (hours
remaining to OFF).
At 5 hours after timer start
The air conditioner comes on, and will
continue to run until someone turns it off.
AFTER
OFF
AUTO OFF
3
1
2
Timer Setting
AFTER
OFF
AUTO OFF
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK
DAY
MONITOR/SET
CLOCK
ON/OFF
2
a 9
4
b
Summary of Contents for CITY MULTI PCFY-P-VKM-E