![Mitsubishi Electric Citi Multi Series Technical & Service Manual Download Page 7](http://html.mh-extra.com/html/mitsubishi-electric/citi-multi-series/citi-multi-series_technical-and-service-manual_237995007.webp)
7
Service Ref.
PLFY-P24NBMU-E2
PLFY-P30NBMU-E2
PLFY-P36NBMU-E2
Power source
1-Phase 208–230 V, 60 HZ
Cooling capacity
(Nominal)
*1
*1
BTU/h
24,000
7.0
30,000
8.8
36,000
10.5
kW
Power input
kW
0.05
0.05
0.09
Current input
A
0.47
0.50
0.87
Heating capacity
(Nominal)
*2
*2
BTU/h
27,000
7.9
34,000
10.0
40,000
11.7
kcal/h
Power input
kW
0.04
0.04
0.08
Current input
A
0.40
0.43
0.80
External finish
Galvanized steel sheet
External dimension H × W × D
in
11-3/4 × 33-3/32 × 33-3/32
298 × 840 × 840
11-3/4 × 33-3/32 × 33-3/32
298 × 840 × 840
11-3/4 × 33-3/32 × 33-3/32
298 × 840 × 840
mm
Net weight
lb [kg]
60 [27]
60 [27]
60 [27]
Decoration panel Model
PLP-40BAU
PLP-40BAU
PLP-40BAU
External finish
MUNSELL (6.4Y 8.9/0.4)
Dimension
H × W × D
in
1-3/8 × 37-13/32 × 37-13/32
35 × 950 × 950
1-3/8 × 37-13/32 × 37-13/32
35 × 950 × 950
1-3/8 × 37-13/32 × 37-13/32
35 × 950 × 950
mm
Net weight
lb [kg]
13 [6]
13 [6]
13 [6]
Heat exchanger
Cross fin
FAN
Type × Quantity
Turbo fan × 1
Turbo fan × 1
Turbo fan × 1
External static
press.
in. WG
0.000 (208 V)
0
0.000 (208 V)
0
0.000 (208 V)
0
Pa
in. WG
0.000 (230 V)
0
0.000 (230 V)
0
0.000 (230 V)
0
Pa
Motor type
DC motor
Motor output
kW
0.050
0.050
0.0120
Driving mechanism
Direct drive
Air flow rate
cfm
565-636-706-777
16.0-18.0-20.0-22.0
267-300-333-367
565-636-706-777
16.0-18.0-21.0-23.0
267-300-333-367
777-883-989-1,059
22.0-25.0-28.0-30.0
367-417-467-500
m³/min
L/s
Noise level (Low-Mid2-Mid1-High)
(measure on anechoic room)
dB <A>
28-31-34-37 (208–230 V)
―
―
28-32-35-37 (208–230 V)
―
―
35-38-41-43 (208–230 V)
―
―
dB <A>
dB <A>
Insulation material
PS
Air filter
PP honeycomb (long life filter, anti-bacterial type)
Protection device
Fuse
Refrigerant control device
LEV
Connectable outdoor unit
R410, CITY MULTI
Diameter of refrigerant
pipe (O.D.)
Liquid
in [mm]
3/8 [9.52] Flare
3/8 [9.52] Flare
3/8 [9.52] Flare
Gas
in [mm]
5/8 [15.88] Flare
5/8 [15.88] Flare
5/8 [15.88] Flare
Field drain pipe size
in [mm]
O.D 1-1/4 [32]
O.D 1-1/4 [32]
O.D 1-1/4 [32]
Standard attachment Document, accessory
Installation Manual, Instruction Book
Optional parts
Air outlet shutter plate
PAC-SH51SP-E
PAC-SH51SP-E
PAC-SH51SP-E
High efficiency filterelement
PAC-SH59KF-E
PAC-SH59KF-E
PAC-SH59KF-E
Multi-function casement
PAC-SH53TM-E
PAC-SH53TM-E
PAC-SH53TM-E
Remarks
Installation
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items
shall be referred to the Installation Manual.
*1 Nominal cooling conditions *2 Nominal heating conditions
Indoor: 80°F D.B./67°F W.B 70°F D.B.
[26.7°C D.B./19.4°C W.B ] [21.1°C D.B.]
Outdoor: 95°F D.B. 47°F D.B./43°F W.B
[35°C D.B.] [8.3°C D.B./6.1°C W.B]
Pipe length: 25 ft [7.6m] 25 ft [7.6m]
Level difference: 0 ft [0 m] 0 ft [0 m]
Note: Due to continuing improvement, above specification may be subject to change without notice.
Unit converter
kcal/h = kW × 860
BTU/h = kW × 3,412
cfm = m3/min x 35.31
lb = kg/0.4536
Above specification data is
subject to rounding variation.
OCH579