12. Transport
For transport, the splitting knife A must be completely moved down.
Slightly tilt the log splitter with handle B on the splitting column until the
machine is inclined on the wheels and can be moved.
13. Storage
Store the device and its accessories in a dark, dry and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and 30˚C.
Cover the electrical tool in order to protect it from dust and moisture.
Store the operating manual with the electrical tool.
14. Maintenance
Attention!
Pull out the power plug before carrying out any maintenance
work on the equipment.
When must the oil be changed?
First oil change after 50 operating hours, then every
500 operating hours.
Oil change
• Completely retract the splitting column.
• Put a container with a volume of at least 6 litres
under the splitter.
• Release the oil dipstick 6.
• Open the oil drain plug 12a under the oil tank so the
oil can flow out.
• Afterwards, close the oil drain plug 12a again.
• Remove the ventilation cap, pour in 4 litres of fresh
hydraulic oil using a clean funnel.
• Screw the oil dipstick in again.
Dispose of the used oil in a correct manner at a
public collection facility. It is prohibited to drop
old oil on the ground or to mix it with waste.
We recommend oil from the HLP 32 range.
6
12a