16
SECTION 2
INSTALLATION
2.1 UNPACKING, STORAGE, RESHIPMENT
Carefully open the shipping container and remove the equipment. Inspect the
equipment thoroughly and report any damage.
If the equipment is to be stored, it should be wrapped in plastic and kept in a clean, dry
place.
If the equipment is to be re-shipped for any reason, wrap the unit in heavy plastic and
ship in a heavy (275-lb. test) double wall carton. At least three inches of a solid packing
material should be used on all sides of the unit. The carton should be marked to indicate
that it contains fragile electronic equipment.
2.2 MOUNTING
THIS EQUIPMENT IS NOT FOR USE IN A DOMESTIC ENVIRONMENT.
THIS EQUIPMENT IS INTENDED FOR RACK MOUNTING.
OPERATOR INJURY MAY OCCUR IF UNIT IS NOT PROPERLY MOUNTED.
THIS EQUIPMENT MUST BE SECURELY MOUNTED.
Slides are provided for mounting the Control Unit in a standard 19" equipment rack.
Physical Arrangement of Converters in a Redundancy Chain
The converter remote interface configuration must be set to RS485, Odd Parity, and
19200 Baud with the following addresses
Backup Unit: Address 64
Primary Unit 1: Address 65
Primary Unit 2: Address 66
Primary Unit 3: Address 67
Primary Unit 4: Address 68
Primary Unit 5: Address 69
Primary Unit 6: Address 70
Primary Unit 7: Address 71
Primary Unit 8: Address 72
Primary Unit 9: Address 73
Primary Unit 10: Address 74
Primary Unit 11: Address 75
Primary Unit 12: Address 76