I
NSTALLING
B
OARDS
AND
C
ABLING
47
21/1531-ASP11301 Uen B3 2016-02-17
5.3.2
FOR 87L00034AAA-A (1U POWER UNIT)
For information, see the documentation delivered with the product. These documents
are also stored in the Alex data base in parallel with this document. See document BCG
00031.44 for Supplier User manual, and document BCG 00133 for Quick Install Guide.
The power system has a set of ports, alarm contacts, located on the rear side, that
reflect different operating conditions for the power supply, see Figure 37: Rear view of
BZA 109 11 on page 46.
Note:
The picture shows the 2U Power Unit but the 1U Power unit has the same
connectors but in another position.
The communication with the AC/DC-unit can also be done via the com-module. The
modules have a RJ45-connector to communicate with the LAN.
5.4
AC/DC ALARM THROUGH MGU
5.4.1
MIVOICE MX-ONE LITE 87L00039XAA-A WITH 1U POWER UNIT
Figure 38: MGU Power Alarm Detection in MX-ONE Lite
The following cables are used:
1.
Power cable TSR 9020279/2000 (free end on power unit side)
2.
Alarm cable 61L00007AAA-A (free end on power unit side)
The alarm cable is optional and is only needed when alarm handling is required.
Rear side of 1U AC/DC
NC NO C
Relay 4
NC NO C
Relay 3
NC NO C
Relay 2
NC NO C
Relay 1
White Blue Turquoise Violet