Mistral MSS10 Operating Instructions Manual Download Page 9

16

17

Installation

1. Secure the mounting plate

 

•  The mounting plate should be attached to the structural part of wall (post etc.)

  NOTE: 

•  Holes indicated by solid arrows must be secured to avoid mounting plate shaking.

   

•  When the expansion bolts are used, two holes (11x20 or 11x26) 450mm apart    

   

 

should be adopted.

2. Drill on the wall

 

•  Confirm the position of holes, and drill holes of ø65mm on the wall.

¢ 

INDOOR UNIT

 

1.  Open the front panel

  2.  Remove the screw from electrical box  

  cover, pull the box cover away from the  
  unit and set aside.

  3.  Remove the screw from fastener, pull the  

  fastener away from the unit and set aside.

  4.  Connect the cable
  5.  Replace the fastener and electrical box cover

¢ 

OUTDOOR UNIT

  WARNING:
 

•  The connecting cables must be clipped together.
•  Special cable must be used to connect indoor unit and outdoor unit. Ensure that the  

 

  terminals are not influenced by external forces. Poor connections may cause a fire.
•  The electric box cover must be mounted and secured in position, otherwise fire or electrical    
  shock may occur because of dust or moisture.
•  If necessary, consult your supply authority for system impedance information.

 

¢ 

CONNECTING PIPE WORK

1.  NOTE:

•  The drain must be arranged beneath the copper pipe.
•  The drain hose must not be hunched or bent.
•  When the drain hose runs through the house, it should  
  be wrapped with special heat insulated materials.
•  The copper pipe and the drain hose must be wrapped  
  by felt strip. Heat insulated pad should be used in the  
  place that the pipe contacts the wall.

2.  ROUTE OF PIPE:

•  If pipe came out of the right side of the indoor unit,    
  cut part "1" on the unit.
•  If pipe came out of the lower-right side of the indoor  
  unit, cut part "2" on the unit.
•  If pipe came out of the left side of the indoor unit, cut  
  part "3" on the unit.

3.  REFIT OF DRAIN HOSE

•  If pipe comes out of the left side of the indoor unit, the  
  drain hose must be refitted otherwise water leakage  
  may occur.
•  Refit methods: Interchange the position of drain hose and  
  drain rubber bib, the right diagram is normal position.
•  Clearance is not possible after refitting as it leads to 
  water leakage.

  WARNING:     

When re-installing the piping and drain hose they should be removed via the  

 

position, otherwise there might be a risk of electric shock.

 

Summary of Contents for MSS10

Page 1: ...Reverse Cycle Split System Air Conditioner MSS10 1HP MSS15 1 5HP MSS20 2HP MSS25 2 5HP...

Page 2: ...e malfunctions of the unit or dew to drip from the unit COMPULSORY WARNING If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in...

Page 3: ...set sleep operation this operation will cancel when the sleep button is repressed 5 Air flow direction adjustment Change up down air flow direction 1 Press the MANUAL SWING button the deflector will...

Page 4: ...of indoor unit 4 FAN mode Press MANUAL SWING button or SWING button to change up down air flow direction Press FAN SPEED button to change the fan speed of indoor unit 5 HEAT mode Press MANUAL SWING bu...

Page 5: ...teries from the remote controller Check before operation CAUTIONS Check that the wiring is not broken and is connected Check that the air filter is installed Check that the outdoor unit air outlet or...

Page 6: ...door outdoor Function heat pump type heat pump type Power 230V 50Hz 230V 50Hz Rated cooling heating capacity W 2000 2400 3500 4000 Standard input power W 750 cool 730 heat 1300 cool 1380 heat Standard...

Page 7: ...it must be replaced by its service agent or similar qualified person in order to avoid a hazard 12 13 Performance Parameters cont Model MSS25 2 5HP indoor outdoor Function heat pump type Power 230V 5...

Page 8: ...E Drain hose 1 6 Remote controller 1 F Opening cap 1 7 Felt 1 G Wall hole cover 1 8 Adiabatic underlay 1 H Indoor wall hole cover 1 9 connecting cable 1 I putty 1 10 Drain joint supplied by customer...

Page 9: ...may occur because of dust or moisture If necessary consult your supply authority for system impedance information CONNECTING PIPE WORK 1 NOTE The drain must be arranged beneath the copper pipe The dra...

Page 10: ...n hose and joint CONNECT CONNECTING PIPE Wipe the air sealing oil on the closing valve and the trump extended pipe Screw down the nut of connecting pipe with the wrench the torque is as the indoor uni...

Page 11: ...f purchase for all parts defective in workmanship or materials The product or defective parts will be replaced free of charge WARRANTY CONDITIONS 1 This warranty is only valid for appliances used acco...

Reviews: