14
15
Installation Sketch
Confirm installation position
with the marker of indoor
unit installation board.
Notice: Do not put the drain
hose higher than the outlet.
The pipe can be configured for
installation to the back, right,
underside, or left-back side
Cover connecting pipe with
heat-isolating material.
The thickness of heat-isolating
material should be 8mm.
When installing connecting
pipe on a wall that is metallic
mesh or thin armour plate,
place a wooden block with
a thickness over 20mm
between the wall and
connecting pipe with 7 or 8
layers of bonding tape.
Installation Accessories
Before installation, inspect the following accessories:
Indoor unit accessories
Quantity Installation accessories
Quantity
1
Mounting plate
1
A
Connecting pipe
1
2
Tapping screw ST4 x 25
5
B
Bonding tape
1
3
Expansion rubber plug
5
C
Clamp
3
4
Expansion bolt
2
D
Cement nail
5
5
Battery
2
E
Drain hose
1
6
Remote controller
1
F
Opening cap
1
7
Felt
1
G
Wall-hole cover
1
8
Adiabatic underlay
1
H
Indoor wall-hole cover
1
9
connecting cable
1
I
putty
1
10
Drain joint
(supplied by customer)
1
J
Air sealing oil
1
K
Shockproof rubber cushion
(supplied by customer)
4
Installation Instructions
1 Location of indoor unit
• Cooled or heated air should be blown to
every part of the room.
• Maximum distance between indoor/outdoor
units is 5m.
• Mount on firm wall to avoid any vibration.
• Avoid direct sunshine.
• Easy drain for condensation water.
• Avoid any interference caused
by a fluorescent lamp to the remote
control's signal.
• Minimum distance between air conditioner
and home appliance (TV/Radio, etc.) is 1m.
2 Location of outdoor unit
• Airflow cannot be blocked.
• Good ventilation, low dust, avoid rain or
direct sunshine.
• Ensure operational noise of air blowing out of
unit does not affect neighbour's comfort.
• Firmly mount on rack, to reduce noise
and vibration.
• Avoid places close to inflammable gas leakage.
• Unit must be mounted firmly when installed
high up.
• Avoid exposure to strong wind.