Mistral MSS10 Operating Instructions Manual Download Page 3

NOTICE

•  If the remote control does not operate 

normally, short circuit the RESET contacts, the 
unit will then operate normally.

•  The remote control will only operate within

a six metre range.

•  Handle remote control carefully. Do not drop, 

throw or allow any moisture to penetrate the 
remote control.

•  When a button is pressed, the indoor unit will 

beep once or twice, indicating the signal has 
been received. If no beep is heard, press again.

•  Remove batteries if the remote control is not 

to be used for a long time.

Remote Controller 

Operation of Air Conditioner

Operating procedure using the 
remote control

1. Start/Stop or On/Off

  •  Press I/O button to start operation, 

  the unit will stop when repressed.

2. Temperature adjustment

  •  Press TEMPERATURE ADJUSTMENT  

  button, decreases by 1˚C by pressing
  "

q

" button once.

  •   The temperature change will display in the  

  remote controller's display.

3. Fan speed adjustment

  •  Pressing FAN SPEED button changes the  

  fan speed of indoor unit in the order of

   

 

(low) 

¨

          (medium) 

¨     

(high) 

¨ 

   

   

(auto)

4. Sleep selection

  •  Press SLEEP button to set sleep operation,  

  this operation will cancel when the sleep  
  button is repressed.

5. Air flow direction adjustment

  •  Change up/down air flow direction
1   Press the MANUAL SWING button, 

the deflector will move to a specific 
angle. Change the deflector of 
indoor unit following the order of 
   (1) 

Ž

    (2) 

Ž

    (3) 

Ž

   (4) 

Ž

    (5)(Fig.2) 

(see page 6). 

2  Press the SWING button, the deflector will 

start to operate.

  •  To change the air flow direction from left  

  to right.

  You can manually adjust the swing deflector, 

Left/Right to change the air flow direction. 
Complete adjustment before operation, 
if adjusted during operation, the auto 
swinging deflector may pinch your fingers. 
(Fig.1) (see page 6).

4

5

Signal ejecting window

OPERATION DISPLAY

TEMPERATURE 

ADJUSTMENT BUTTON

ON/OFF BUTTON

FAN SPEED BUTTON

SWING BUTTON

MANUAL SWING 

BUTTON

OPERATION MODE 

BUTTON

TIME OFF BUTTON

TIME ON BUTTON

TIME CANCEL BUTTON

TIME SET BUTTON

SLEEP BUTTON

RESET BUTTON

1.  Open back cover, put in batteries.

2.  Short circuit reset contacts with forceps. 

(Short two RESET buttons after changing 
the batteries).

Remote Control 
Preparation

Battery Compartment

•  Ensure batteries are inserted 

in the correct direction.

•  Do not mix battery types.
•  When replaceing, 

ensure both batteries are 
changed simultaniously.

Summary of Contents for MSS10

Page 1: ...Reverse Cycle Split System Air Conditioner MSS10 1HP MSS15 1 5HP MSS20 2HP MSS25 2 5HP...

Page 2: ...e malfunctions of the unit or dew to drip from the unit COMPULSORY WARNING If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in...

Page 3: ...set sleep operation this operation will cancel when the sleep button is repressed 5 Air flow direction adjustment Change up down air flow direction 1 Press the MANUAL SWING button the deflector will...

Page 4: ...of indoor unit 4 FAN mode Press MANUAL SWING button or SWING button to change up down air flow direction Press FAN SPEED button to change the fan speed of indoor unit 5 HEAT mode Press MANUAL SWING bu...

Page 5: ...teries from the remote controller Check before operation CAUTIONS Check that the wiring is not broken and is connected Check that the air filter is installed Check that the outdoor unit air outlet or...

Page 6: ...door outdoor Function heat pump type heat pump type Power 230V 50Hz 230V 50Hz Rated cooling heating capacity W 2000 2400 3500 4000 Standard input power W 750 cool 730 heat 1300 cool 1380 heat Standard...

Page 7: ...it must be replaced by its service agent or similar qualified person in order to avoid a hazard 12 13 Performance Parameters cont Model MSS25 2 5HP indoor outdoor Function heat pump type Power 230V 5...

Page 8: ...E Drain hose 1 6 Remote controller 1 F Opening cap 1 7 Felt 1 G Wall hole cover 1 8 Adiabatic underlay 1 H Indoor wall hole cover 1 9 connecting cable 1 I putty 1 10 Drain joint supplied by customer...

Page 9: ...may occur because of dust or moisture If necessary consult your supply authority for system impedance information CONNECTING PIPE WORK 1 NOTE The drain must be arranged beneath the copper pipe The dra...

Page 10: ...n hose and joint CONNECT CONNECTING PIPE Wipe the air sealing oil on the closing valve and the trump extended pipe Screw down the nut of connecting pipe with the wrench the torque is as the indoor uni...

Page 11: ...f purchase for all parts defective in workmanship or materials The product or defective parts will be replaced free of charge WARRANTY CONDITIONS 1 This warranty is only valid for appliances used acco...