Revision 1.00 beta – April 2019
27
Enable VOX in menu 10. Default value is off. Adjust VOX Gain from 1 – 10. Position
10 is most sensitive and can be activated from surrounding noises.
Enter menu 9 to set delay on SSB (default is 0.5S)
8. CAT/PC connection.
RGO ONE has built in FTDI USB to serial UART interface chip that allows PC/CAT
connection. Connection is done via USB type B connector located on rear panel of the
radio 11 (fig.2).
CAT protocol
RGO ONE uses widespread KENWOOD type protocol
Establish connection.
When the radio and PC are connected check which virtual port has been used (My
computer - Device manager – Ports COM and LPT).
Assign same virtual com port in your computer logging/contest program.
Enter menu 22 and select communication speed. Assign same comm speed in
computer logging/contest program.
DTR, RTS signals
Some logging/contest programs may use UART signals DTR and RTS for CW keying
(manipulation) and PTT line control. To enable these functions enter menu32 and 33
and make them ON or OFF.