background image

I & II Power Supply 

Power Factor Corrected AC-DC Switcher 

Overview 

The Javelin is a ruggedized, switching power supply that combines the advantages of power factor correction 
and power density with user-selectable output voltage and power.  Accepting input voltages of 85 to 254 VAC 
and 85 to 380 VDC, the Javelin can provide up to 1800 watts in a 4.9

 H x 7.0

 W x 10.75

 L (9.5

 L for Javelin 

II) package.  Its inherent flexibility comes from its use of Vicor 2

nd

 Generation DC-DC converters. Javelin I has 

a 100 CFM fan installed, while Javelin II utilizes customer-provided forced-air cooling. 

Standard Features

 

 

Power Factor Correction:  .99 at 115 VAC; .95 at 230 VAC. 

 

Universal Input:  85-254 VAC, 47-500 Hz, or 85-380 VDC. 

 

Power Output:  1800W at 230 VAC for selected outputs; 800W at 115 VAC (See Graph 1, Pg 13, for 
breakdown of input voltage vs. output power). 

 

Full power to 55

C; half power at 70

C . (See Graph 2, Pg 14 for breakdown of output power vs. ambient 

temperature.) 

 

Soft start for limiting inrush current. 

 

EMI Compliance: FCC Class A; EN 55022 Class A & B; MIL-STD-461E. 

 

Transient Protection: MIL-STD-704E. 

 

Environmental:  MIL-STD-810E. 

 

MIL-STD-1399 (300A); 115VAC, 60Hz, single phase; 

1KVA

5KVA. 

 

Harmonic Distortion to EN61000-3-2. 

 

AC Power OK status signal. 

 

Fan cooled (Javelin I only, Javelin II requires 100 CFM to be provided by customer). 

 

Equipped with Auto-Sense. 

 

Output overcurrent, overvoltage and overtemperature protection. 

 

Ride-through (holdup) time: 

20 ms at 1200W load. 

 

Size:  4.9

 H x 7.0

 W x 10.75

 L (9.5

 L for Javelin II). 

 

Heavy-duty “ruggedized” enclosure designed for a high shock and vibration environment. 

 

Extra cooling provided for higher output with increased altitude capability. 

 

“D” shell connectors for input and interface connections. 

Technical Description

 

The Javelin consists of a DC or off-line single phase power-factor-corrected front end, with an EMI filter, cool-
ing fan (Javelin I), customer interface, associated housekeeping circuits, and a selection of Vicor’s DC-DC con-
verters. 

 

Input DC or AC mains voltage is applied to a 3-pin power connector.  The input current is passed through an 
EMI filter designed to meet conducted noise limit specification EN55022, level A and B. 

 

At start-up, inrush current is limited by a PTC thermistor.  The PTC is shunted out shortly after initial power-up 
by  a  DC  bus  voltage  sense  circuit  driving  a  thyristor.    After  rectification,  the  input  voltage  is  put  through  a 
boost  converter  that  keeps  the  AC  input  current  sinusoidal  and  synchronized  with  the  input  AC  voltage  (in 
compliance with EN61000-3-2).  The boost converter delivers a regulated input to the hold-up capacitors and a 
high voltage backplane.  The backplane supplies power to the DC-DC converters that provide the desired low 
voltage, regulated output. 

Rev. 05/11/2012    Mission Power Solutions        (760) 631-6846          [email protected]             Pg. 4

 

Javelin I & II Power Supply Operator’s Manual 

Summary of Contents for Javelin I

Page 1: ...Supply Operator s Manual I II Power Supply Power Factor Corrected AC DC Switcher Operator s Manual and Quick Install Instructions www mpwrs com Rev 05 11 2012 Mission Power Solutions 760 631 6846 sal...

Page 2: ...e Phase DC A1 L1 A1 A2 L2 N A2 A3 Earth Gnd A3 Earth Gnd Table 1 AC and DC Input Connections Status Control Connector J2 J2 1 and J2 9 are spare pins and are not used J2 2 and J2 4 are Signal Return p...

Page 3: ...sitive load con nection and pin J3 6 to the negative load connection Attach load end of sense lines at the point where regulation is desired J3 2 and J3 8 provide DC OK and DC OK signals J3 3 and J3 7...

Page 4: ...ith Auto Sense Output overcurrent overvoltage and overtemperature protection Ride through holdup time 20 ms at 1200W load Size 4 9 H x 7 0 W x 10 75 L 9 5 L for Javelin II Heavy duty ruggedized enclos...

Page 5: ...power output to come up 15 30 ms later An auxiliary Vcc output of 5 VDC capable of sourcing up to 300mA is provided for peripheral use An output Inhibit Enable function is provided by using an optocou...

Page 6: ...ame as Earth Ground on input power connector J1 Inhibit Enable J2 7 to J2 8 The Inhibit Enable control pins allow the output to be controlled with either inhibit or enable logic Con necting Inhibit J2...

Page 7: ...voltage drop along the output power cables the output can be trimmed up or configured for Remote Sense Use stranded twisted pair 20 24 AWG wire for the Remote Sense lines Remote Sense can compensate f...

Page 8: ...nals i e a fuse Use proper size wires to avoid overheating and excessive voltage drop Do not attempt to repair or modify the power supply in any manner Do not restrict airflow to the unit The cooling...

Page 9: ...Javelin I II Power Supply Operator s Manual Mechanical Drawing Javelin I Rev 05 11 2012 Mission Power Solutions 760 631 6846 sales mpwrs com Pg 9...

Page 10: ...Javelin I II Power Supply Operator s Manual Mechanical Drawing Javelin II page 1 Rev 05 11 2012 Mission Power Solutions 760 631 6846 sales mpwrs com Pg 10...

Page 11: ...Javelin I II Power Supply Operator s Manual Mechanical Drawing Javelin II page 2 Rev 05 11 2012 Mission Power Solutions 760 631 6846 sales mpwrs com Pg 11...

Page 12: ...W load Transient Surge IEC 801 5 level 3 Common Mode Normal Mode Dielectric Withstand Primary to Chassis GND 2121 VDC Primary to Secondary 4242 VDC Secondary to Chassis GND 500 VDC Output Parameter MI...

Page 13: ...ower 55 C to 55 C M Grade Half Power 55 C to 70 C Product Weight 11 50 lbs 11 0 lbs Javelin II Dimensions 4 9 H 124 46mm x 7 0 W 177 8mm x 10 75 L 273 1mm 9 5 L 241 3mm for Javelin II Warranty 1 Year...

Page 14: ...00 1200 1400 1600 1800 2000 0 20 40 60 80 100 Pout max Temperature Ambient C Maximum Output Power vs Temperature 400W 600W 800W 1200W 1600W 1800W Rev 05 11 2012 Mission Power Solutions 760 631 6846 sa...

Page 15: ...Javelin I II Power Supply Operator s Manual Rev 05 11 2012 Mission Power Solutions 760 631 6846 sales mpwrs com Pg 15 Notes...