P A G E 1 1 O F 1 7
M I S S I ON S OL A R E NE R G Y L L C
ELECTRONIC
versions are uncontrolled except when accessed directly from document control directory. Printed copies are uncontrolled unless verified against online document.
C OP YR I GH T 2 0 2 0 M I S S IO N S OL A R E N ER GY L L C , AL L R I G H T S R ES E R V ED
REVISION: R2
RELEASE DATE: 9/25/2020
TABLE 7: DESIGN LOAD AS SPECIFIED BY UL61730
INSTALLATION
TYPE
MODULE
*MOUNTING DISTANCE
[D]
FRONT OF MODULE
DESIGN LOAD
BACK OF MODULE
DESIGN LOAD
Bolt method
SX6S / SX6W / SX6Z
546mm
3600 Pa
1600 Pa
SX6R
506mm
3600 Pa
1600 Pa
SX5T / SX5K
470mm
3600 Pa
1600 Pa
Clamp method
SX6S / SX6W / SX6Z
469mm < D ≤ 546mm
3600 Pa
1600 Pa
469mm
3600 Pa
2400 Pa
SX
5
R
429mm < D ≤ 506mm
3600 Pa
1600 Pa
429mm
3600 Pa
2400 Pa
SX5T/SX5K
393mm < D ≤ 470mm
3600 Pa
1600 Pa
393mm
3733 Pa
3754 Pa
*Mounting Distance [D] – distance between edge of module and middle of clamp (or mounting hole) location. This is assuming that modules are
mounted on a certified mounting system.
FIGURE 1: BOLT METHOD
FIGURE 2: CLAMP METHOD
Note:
Allowable clamp minimum
dimensions are as follows:
DIMENSION
mm
in
A
9
.35
B
38
1.5