GUIDE TO INSTALLATION AND OPERATION
•
Remote System Administration – opens the Joining Locators data box,
which lists remote lookup services to which this IRD-3111 is registered.
Add:
Force the iControl service for this IRD-3111 to register itself on
a user-specified Jini lookup service, using the following syntax in the
data box:
jini://<ip_address>
where <ïp_address> is the ip address of the server running the
lookup service, e.g.:
Remove:
select one of the services listed in the window by clicking on it, and click
Remove
to open a query
box allowing you to delete it from the window.
3.4.18.2 Message Console tab
The Message Console provides a log of various status
messages generated on-board the card.
•
Newest messages appear at the bottom of the list
•
Use the scroll bar to view the entire list
Click the
Clear Messages
button to empty the message
window.
This panel is primarily provided for diagnosis purposes.
Hardware and transport stream error messages are sent to
this panel, along with card activity status reports.
Reset Card…:
Use this button to reset the card.
For various reasons, some CAM cards may stop
decrypting, stop passing the stream or even freeze. When
that happens, the only way to recover is to reset the
CAM. This involves putting it through a power off/power
on cycle. This can be done by physically removing it from
its slot and then reinserting it. Alternatively, resetting the
IRD-3111 will also reset the CAM, and this can be done
remotely via this iControl panel
Figure 3.46 Joining Locators
Figure 3.47 Message Console
IRD-3111 |