22
Shower cubicle, laminated panel or stud partition wall Installation
Read the section
“Installation Requirements”
first.
The bir spray head should be positioned at a convenient height for all the family. It
should be positioned so that it discharges down the centre line of the bath, or across
the opening of the shower cubicle and it should be directed away from the shower
control. The pipework between the shower control and the backplate nut of the shower
head is not supplied as part of the shower fitting.
ø
5.5 mm
ø
25 mm
ø
5.5 mm
1.
Cut a 25 mm hole in the panel and two
5.5 mm holes at 48 mm centres.
2.
Feed the copper pipe through the
mounting plate and panel. Ensure the
pipe protrudes
at least 23 mm
from
wall.
3.
The copper pipe must protrude through
the wall between 23 - 25mm from the
finished surface of the wall. If the pipe
protrudes further than 25mm it will
prevent the backplate nut from
engaging with the backplate. If
necessary cut the pipe to the correct
length and remove any burrs.
4.
Hold the mounting plate in position
behind the panel, place the backplate
in front of the panel and insert the two
backplate screws through the holes
in the panel and fit them into the
mounting plate and tighten.
5.
To complete the installation of the bir
fittings follow instructions 13. to 18.
of
"Solid and Dry-lined Wall
Installation"
on Page 18.
Mounting Plate
Panel
Screws
48 mm
23 to 25 mm
Wall Plate
15 mm
Copper Pipe
Finished Wall
Surface