10.
Finish the surface of the wall as
required.
11.
The copper pipe must protrude through
the wall between 23 - 25mm from the
finished surface of the wall. If the pipe
protrudes further than 25mm it will
prevent the backplate nut from
engaging with the backplate. If
necessary cut the pipe to the correct
length and remove any burrs.
7.
Drill the four mounting plate fixing
holes. If necessary, make a recess
approximately 6 mm deep to accept
the mounting plate. Fit the four wall
plugs supplied to the fixing holes.
8.
Fix the mounting plate to the wall with
four screws (not supplied). The two
threaded holes must be horizontal.
9.
Temporarily fit the two backplate
fixing screws into the mounting plate.
This will prevent the fixing holes from
becoming blocked with plaster or
grout.
Mounting Plate
Threaded
Holes
6.0 mm
Mounting Plate
Temporarily fit the
two backplate
fixing screws to
prevent holes
becoming blocked
with grout.
23 to 25 mm
15 mm
Copper Pipe