8
Installing the Thermostatic Mixer
1.
The thermostatic mixer must be fitted vertically
as illustrated and can only be installed with
rear supply inlets. The supply pipework
must
be connected as follows:
•
Cold to Top Inlet
•
Hot to Bottom Inlet
•
Bottom Outlet.
Important!
This product does not allow for
reversed inlets.
2.
Determine the route for the hot and cold supply
pipework.
Important!
Make sure that there is sufficient
headroom and ceiling clearance to install the
integral slidebar.
3.
Loosen the 2 backplate grubscrews with the
2 mm hexagonal key (supplied) and pull the
mixer and concealing plate from the backplate.
4.
Unscrew the inlet nuts from the backplate.
Cold
Outlet
Hot
Concealing
Plate
Backplate
Inlet Nuts
5.
Using the backplate as a guide, mark the
positions of the fixing holes and the pipe
centres.
Important!
Make sure that there is sufficient
headroom and ceiling clearance to install the
integral slidebar.
Note!
Make sure that the backplate is the
correct way up (refer to illustration).
Large boss
must
be
fitted at the bottom
Grubscrew