15
1.10.
Drill and plug the top two fixing holes. Secure the Mira Go to the wall with the
screws provided. Drill the bottom fixing hole with the product in place.
Alternative fixings (not supplied) may be necessary for some wall structures.
Avoid drilling into any supply cable/pipe.
1.11.
Install the mains-fed cold water supply pipe.
Installation of the Mira Go
Service Tunnel
Inlet Connector
Assembly
Cold Water
Supply Pipe
Bottom Entry
Terminal Block
Cover Retaining
Screw
Holes For Cover
Retaining Screws
(The inlet
connector
assembly can be
swivelled to suit the
supply)
Do not
fit the Mira Go to the
wall and tile up to the case.
The Mira Go must be fitted
on to
a finished flat and
even wall surface (small
pillars moulded on to the
back of the case allow air
circulation).
(The service tunnel
or case may be
trimmed to suit
rising or falling
supply)
Fixing Screw
Splash Guard
(Make sure that it is
secured before operating
the shower).
Electrical Supply
Cable
Electrical
Rear Entry
Cold Water
Top Entry