Installation Requirements
Section
6
Specifications
1. Plumbing
1.1.
Minimum maintained inlet pressure 0.7 bar for satisfactory operation.
1.2.
Maximum static inlet pressure 10 bar.
1.3.
Minimum static pressure 0.2 bar to maintain product shut-off.
2. Electrical
2.1.
The Mira Go requires a 40 Amp fuse in the consumer unit.
2.2.
The terminal block will not accept cable larger than 10 mm
2
.
3. Standards and Approvals
3.1.
This Mira Go complies with all relevant directives for CE marking.
1. Plumbing
1.1.
The Mira Go is designed to operate with a minimum
maintained inlet pressure
of 0.7 bar
up to a
maximum static inlet pressure of 10 bar.
1.2.
The Mira Go is normally connected to the cold water mains-fed supply.
However, the water supply can be taken from a cold water storage cistern,
provided there is a minimum maintained inlet head of water of 7 metres (the
vertical distance from the base of the cold water storage cistern to the shower
fitting handset). To reduce pressure losses and fluctuations, the cistern-fed
water supply must be independent from other supply draw-offs, and should
avoid long horizontal pipe runs and use swept bends rather than 90 ° elbows.
If you can only cistern feed your shower and you do not have a 7 metre head
required for correct operation, Mira produce a pumped electric shower (Elite 2)
designed for this particular application.
1.3.
The Mira Go is suitable for installation within the shower area. It is fitted with
a pressure relief device and must be positioned over a water catchment area
with the controls at a convenient height for the user.