Mira Advance ATL J97A Installation Manual Download Page 28

28

Advance Error Codes / Display, Causes and Rectification 

All fault codes will require the shower to be turned off at the pullcord / isolator switch to reset the 

unit. When the pullcord / isolation switch is turned back on the shower may beep and the Start 

/ Stop button may flash. If this occurs go back to action number 2 and re-follow the Diagnostic 

Procedure

Error Code Indicator Display Possible Cause/Rectification

A

OR

Problem with water supply, unit still operates.
1. 

Check all isolator valves are fully open.

2. 

Clean / replace filter, refer to section: 

'

Maintenance'

.

3. 

Blocked Hose / showerhead.

4. 

Check Inlet Temperature not too high.

0

An unidentified error has occurred.

1. 

Replace Control PCB / Cover.

1

Incoming flow too low for appliance to operate 

safely. 
1. 

Check all plumbing isolator valves to the 

shower are turned fully on

2. 

Reset - Commission the shower.

3. 

Blocked or partially blocked filter, hose or 

showerhead .

4. 

A section of the supply pipe may be frozen 

(thaw). (Advise customer of incorrect 

installation)

5. 

Replace Flow Valve.

6. 

Replace Thermal Switch.

7. 

Replace Heater Tank.

2

Internal electrical supply problem.
1. 

Replace Relay Board.

2. 

Replace Control PCB / Cover.

3. 

Replace Thermal Switch.

3

4

Appliance has been incorrectly shut down.
1. 

Replace Relay Board & Control PCB / 

Cover TOGETHER.

Advise the user on correct start/stop procedure  

and general operation of the shower, refer to 

User Guide.

Summary of Contents for Advance ATL J97A

Page 1: ...is product is suitable for mains fed cold water only Installation Guide Mira Advance ATL ADJUSTABLE TEMPERATURE LIMIT THERMOSTATIC 9 0 and 9 8 kW For SPARES ADVICE or REPAIRS Please call us on 0844 57...

Page 2: ...chematic Diagram Drain Pump 17 Instantmatch by Whale Digital Pump 18 Wireless Installation 19 Wireless Signal Schematic Diagram 19 Drain Pump Registration 20 Drain Pump Test 20 Registration or Test Fa...

Page 3: ...ault Diagnosis 25 1 Installer Troubleshooting Guide 26 2 Diagnostic Procedure 27 BEAB Care In Service Tests 32 Maintenance 35 Spare Parts and Accessories 36 Wiring Diagram 38 Customer Service Back Cov...

Page 4: ...of two years from the date of purchase shower fittings for one year Fornon domesticinstallations MiraShowersguaranteetheMiraAdvanceATLagainst anydefectinmaterialsorworkmanshipforaperiodofoneyearfromth...

Page 5: ...st be turned off at the mains and the appropriate circuit fuse removed if applicable 4 Mains connections are exposed when the cover is removed 5 Refer to the wiring diagram before making any electrica...

Page 6: ...on Installation Requirements CAUTION 1 Read all of these instructions and retain this guide for later use 2 The electrical installation must comply to BS 7671 commonly referred to as the IEE Wiring Re...

Page 7: ...n Template 1 x Guarantee Registration Document 1 x Olive 1 x Compression Nut 1 x Mira Advance ATL Standard or Standard Extra Instantmatch by Whale Pump supplied separately Or Or 1 x Mira Advance ATL M...

Page 8: ...ch 45 Amp Double pole with 3 mm contact separation Maximum Ambient Temperature 30 C Minimum Ambient Temperature 2 C Recommended dynamic pressure of 100 kPa 1 0 bar for full flow performance Static pre...

Page 9: ...own condition If pipework and or electrical cables enter the shower from the rear through a hole in the wall provision must be made to prevent water ingress back into the wall structure Route cable an...

Page 10: ...tallation always provide mechanical support when making plumbing connections Upon completion of the installation ensure connections and back case are not under any stress due to misaligned pipework or...

Page 11: ...DO NOT exert strain on the terminal block Make sure that the electrical connections are tightly screwed down 2 5 DO NOT turn on the electrical supply until the plumbing has been completed 2 6 Unless o...

Page 12: ...low Valve Solenoid Connector Lead Socket Thermal Switch Element Assembly Clip secures thermal switch Outlet Sensor Connector Lead Sockets for the Flow Valve Turbine and Inlet Sensor and the Tank Assem...

Page 13: ...mation on position of wireless devices 3 Remove cover screw 5 Turn inlet connector to suit supply pipe Do not trap green wire 6 C o m p l e t e a n y soldering required away from appliance 8 D O N O T...

Page 14: ...e product by using this template to mark and drill into the wall Drill appliance case separately Do not use alternative screws to secure the cover Do not seal any part of the appliance Use the correct...

Page 15: ...block 20 Do not use alternative screws to secure cover This can cause internal damage to appliance Do not seal around any part of appliance 21 Install shower fittings Refer to separate Installation a...

Page 16: ...accessory 1 1759 125 not included Hardwire cable included For use with the Whale Instant Match Pump Wireless Instant Match For use with the Whale Instant Match Pump Wireless Instant Match J97H 32 11 A...

Page 17: ...al Outlet Double Checkvalve 45 Amp Double pole Isolating Switch Mains Fed Cold Water Supply Signal Cable Connector Optional Consumer Unit Isolating Valve Unswitched Spur Instant Match Transformer Inst...

Page 18: ...IVER SIGNAL Jumper location Mira Advance Flex Extra Wireless J97P only TYPE Drain Pump Shower Type Driver Signal 755 171 LK1 Hardwired 755 199 LK1 Hardwired 755 299 LK2 Hardwired 755 349 LK2 Hardwired...

Page 19: ...ll reduce the operational range of any radio controlled product dramatically Interference from other radio signals can also reduce the ability of the shower and drain pump to register or communicate T...

Page 20: ...ng signal interference are temporarily switched off Drain Pump Test 1 Set shower temperature to FULL COLD 2 Shower is OFF NO water is flowing Power Electric to shower is OFF Power Electric to pump is...

Page 21: ...er Check jumper position inside shower cover is set to WIRELESS Drain pump STARTS but shower is NOT RUNNING Solution Shutdownshoweranddrainpumpandreregisterusingtheinstructions below 1 Power to shower...

Page 22: ...there is no water after 5 seconds make sure that appliance has been primed 5 secs 2 Power to appliance check Start Stop for blue light 6 Push Start Stop to turn off appliance Pulsing light and beep in...

Page 23: ...STOPPED flowing Power Electric is OFF 3 Turn Power Electric ON Within 30 seconds push and hold FLOW START STOP together OFF ON 2 Set Maximum Temperature Turn the dial to the desired position in the ta...

Page 24: ...TOP to turn shower ON Check that maximum temperature is acceptable to the user COMMISSIONING FAILURES the commissioning cycle was stopped due to an error No flashing FLOW LIGHT solution Restart the co...

Page 25: ...ve passed before starting the commissioning cycle Memory Model If the maximum temperature is adjusted after it has been stored in one or more of the memory buttons refer to section Operation Storing t...

Page 26: ...ving the front cover and reconnect when maintenance is complete Mains connections are exposed when the cover is removed Refer to wiring diagram before making any electrical connections Make sure all e...

Page 27: ...the shower off at the Start Stop Button observe phased shutdown DO NOT isolate the power at the pullcord isolator switch until the water flow stops 5 Turn off the power at the pullcord isolator switc...

Page 28: ...Check Inlet Temperature not too high 0 An unidentified error has occurred 1 Replace Control PCB Cover 1 Incoming flow too low for appliance to operate safely 1 Check all plumbing isolator valves to th...

Page 29: ...heck relay contacts Debris on contacts or welded closed 2 Check Ribbon Cable Connection 3 Replace Relay Board 4 Replace Control PCB Cover 5 Replace Thermal Switch 9 10 Internal Electrical Supply probl...

Page 30: ...Error lights when unit is re started This error occurs when the shower has been incorrectly shutdown and the unit senses over temperature refer to ERROR 17 Advise the user on correct start stop proced...

Page 31: ...is position 1 a Turn shower off and isolate electric power b Choose channel number 2 or 3 with the temperature control c Repeat steps 2 4 of the Drain Pump Registration instructions found in this gui...

Page 32: ...y major repair If there is no significant change in the outlet water temperature greater than 1 C between the two inspections the in service test frequency may be reduced but must not exceed 12 months...

Page 33: ...er flowing from the showerhead and measure the temperature of the water flowing from the funnel The temperature must be no more than 2 C above the maximum temperature setting Record the temperature on...

Page 34: ...g details of all measurement equipment used This form is available to download at www mirashowers co uk Date Not Operating Normal Operation Restricted Supply Date Signature Terminal Block Voltage V In...

Page 35: ...n cable from cover 3 Hold a spanner or other suitable grips across flats of the metal connector Unscrew filter using another spanner as shown Clean or replace filter as necessary Refit filter making s...

Page 36: ...149 Flow Valve Assembly components identified C 1643 251 Cover and PCB Assembly Standard 1643 252 Cover and PCB Assembly Flex 1643 255 Cover and PCB Assembly Memory 1643 262 Cover and PCB Assembly Fle...

Page 37: ...37 B 1829 062 1643 100 1643 101 1643 102 1643 103 1643 104 1643 105 1643 144 1643 105 1643 144 1643 251 1643 252 1643 255 1643 262 1643 112 B B B B 1643 114 C A C 416 38 A C 1829 063...

Page 38: ...eparation L E Control Board CN8 Green Y Terminal Block Outlet Temperature Sensor One Shot Thermal Switch Blue Heater Tank Plumbing Connectors Outlet Inlet Pump Driver Board Fitted to Standard Extra an...

Page 39: ...39 NOTES...

Page 40: ...of the product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or...

Reviews: