21
6.
Press
START/STOP
.
Registration or Test Failure
•
See
'Wireless Installation'
for examples of devices/objects that could be causing
signal interference. Make sure all such devices are temporarily switched off, then
reregister using the instructions below and retest the drain pump.
•
Attempt to improve the signal strength by moving the drain pump transformer,
then reregister using the instructions below and retest.
•
Shower STARTS, but drain pump is NOT RUNNING.
Solution
.....Isolate power and remove shower cover. Check jumper
position inside shower cover is set to WIRELESS.
•
Drain pump STARTS, but shower is NOT RUNNING.
Solution
.....Shut down shower and drain pump and reregister using the instructions
below.
1.
Power to shower
OFF
.
2.
Push and hold
PUMP SWITCH
until light goes from
GREEN
to
RED/GREEN
.
3.
Within 30 seconds turn power to shower
ON
.
4.
Beep from shower.
5.
PUMP SWITCH
light changes to
GREEN
.
6.
Turn on shower to confirm shower and pump are operating together.
8.
Pump will
START
. Any delay will depend upon
the plumbing layout, but pump should start within
10 SECONDS
.
9 .
Pump and shower work normally.
A test failure is indicated by the following:
•
Shower and pump stop.
• 1 beep and all lights flash 6 times.
R
7.
Shower will
START
.