Thank you for purchasing a quality Mira product. To 

enjoy the full potential of your new product, please 

take time to read this guide thoroughly, having 

done so, keep it handy for future reference.
Mira showerheads are designed to give a 

satisfactory shower over a range of pressures. 

These showerheads are suitable for pressures 

between 0.1 and 5.0 bar.

General

1.

  Installations must comply with Water 

Regulations (Bye-Laws, Scotland), and 

any other Local Regulations and Building 

Regulations in force at the time of 

installation.

2.

  Before installation carefully inspect the product 

for any signs of damage.

Guarantee

For 

domestic installations

, Mira Showers 

guarantee the products listed in this guide against 

any defect in materials or workmanship for a 

period of 

one

 year from the date of purchase.

For terms and conditions refer to the back cover 

of this guide.

Patents and Design Registration

Patent Applications:

UK: 

0715612.8, 0804172.5

World: PCT/GB2008/002703

Design Registration:

Europe: 001004022

FLOW RATES

The flow rates for the Mira 360 showerheads are 

listed below.

Spray Pattern

Inlet Pressure 

0.5 bar

Inlet Pressure 

0.1 bar

Rain

12.3 l/min

5.4 l/min

Storm

11.5 l/min

5 l/min

Burst

7 l/min

3.3 l/min

Cloud

4.2 l/min

Cloud LC

2.7 l/min

USER MAINTENANCE

If you require a Mira trained service engineer or 

agent, refer to section: 

‘Customer Services’

.

Fault Diagnosis

Symptom:

• 

Sprayplate assembly blocked.

Cause / Rectification:

• 

Clean the sprayplate.

—————————————

Symptom:

• 

Drip from sprayplate assembly.

Cause / Rectification:

• 

A  small  amount  of  water  may  be  retained 

in the showerhead after the shower control 

has  been  turned  off.  This  may  drain  over 

a  few  minutes.  Changing  the  angle  of  the 

showerhead may vary the draining time.

—————————————

Symptom:

• 

Poor spray pattern from the Cloud sprayplate 

assembly.

Cause / Rectification:

• 

Change the Cloud sprayplate assembly for 

the LC (Low Capacity) version.

 Caution! 

The LC sprayplate 

must

 not be used 

on electric showers

—————————————

Summary of Contents for 360m

Page 1: ...1 INSTALLATION USER GUIDE These instructions must be left with the user MIRA 360m SHOWERHEAD MIRA 360r SHOWERHEAD MIRA 360i SHOWERHEAD 360r 360i 360m...

Page 2: ...rkmanship for a period of one year from the date of purchase For terms and conditions refer to the back cover of this guide Patents and Design Registration Patent Applications UK 0715612 8 0804172 5 W...

Page 3: ...3 OPERATION 4 5 1 2 6 3 7 8 Rain Storm Cloud Burst Turn the showerhead in the direction shown to activate the different spray patterns...

Page 4: ...e sprayplate must be regularly cleaned to make sure that the showerhead does not become blocked Spray Plate Assembly 1 Use a suitable tool to remove the grommets 2 Using the 2 5 mm hexagonal wrench su...

Page 5: ...ion The LC sprayplate must not be used on electric showers 1 Use a suitable tool to remove the grommets 2 Using the 2 5 mm hexagonal wrench supplied remove the screws 3 Separate the sprayplate assembl...

Page 6: ...ly black 1688 164 Cloud Assembly white 1688 165 Cloud Assembly black 1688 166 Burst Assembly white 1688 167 Burst Assembly black 1688 372 Seal Screw Pack components identified A 1688 169 360i Handle 1...

Page 7: ...7 360r 360i 1688 160 1688 164 1688 275 1688 162 1688 166 1688 161 1688 165 1688 276 1688 163 1688 167 1688 169 A A A A A A 1688 202 1688 203 1688 204...

Page 8: ...our installer help and advice If you experience problems check in this manual to see if simple home maintenance is required If you require further assistance call our Customer Services Team Helpdesk S...

Reviews: