MIOX RIO Series Operators Manual
P/N: 102-00076-G
Page 64
System Display
Fault
Cause
(most likely to least)
Remedial Action
Low H
2
O Temp
Feed water
temperature <40° F
1.
Feed water
temperature
too low
2.
Cell inlet
thermowell
failure
3.
Thermowell
fuse failure
1.
Check feed
water
temperature.
Contact MIOX
Customer
Service if <40°
F
2.
Replace
thermowell
3.
Check fuse F18
on control
interface board
(Figure 34)
DA System Failure
External Dilution Air
(DA) signal in fault
condition
1.
Dilution Air
system failure
2.
External
Dilution Air
system not
used
1.
Correct
external
Dilution Air
system failure
2.
Place jumpers
across input
according to
wiring diagram
Cell Current Variation
Large variation of
current between cell
modules and exits
1.
Current sensor
failure
2.
Cell worn out
3.
Loose
connection at
cell leads
1.
Determine
which sensor
failed using a
DC amp meter
2.
Contact MIOX
Customer
Service to
replace cell
3.
Verify leads are
tightened to
torque
specification.
See “Cell
Installation and
Removal” in
this manual for
additional info.