Monthly Maintenance
Check Power
– Verify that AC supply voltage is within 480 VAC +/-10% for
standard units. For 400V units, verify it is within 400 +/- 10%.
Toggle Day Tank Float Switch
– The system is in standby when both floats are up.
At this point, manually push both floats down to verify that the system operates.
Floats should move smoothly approximately 1/2” in either direction. When both
floats are pushed down, the OSG will come out of stand-by and begin oxidant
solution production
Quarterly Maintenance
Clean Brine Tank
– Using a wet rag, wipe down the interior of the brine generator
tank wall to remove any dirt or buildup.
Clean or Replace the Brine Filter and Water Filter
– The brine and water filters
are the same 5-micron standard type unit for removal of particulate matter. The
brine filter and water filter are located prior to the water softener or OSG. The OSG
should be off or in standby mode when filters are removed or replaced. Visually
inspect the filter for clogging and debris. If flow is restricted, the filter should be
replaced. Reinstall the filter. Discard the old filters according to local environmental
codes.
Check Controls Wiring Connections
– Electrical heating and cooling cycles may
loosen connections. After turning OSG power off, check all connections for tightness
by gently tugging on them. Tighten any loose screws or bolts. Wires should be clean,
dry, and corrosion-free.
Annual Maintenance
Drain and clean the brine generator every year to remove build-up that can be up to
several inches thick. Drain and clean the oxidant solution tank annually to remove
particulates. Avoid any ignition sources in the vicinity of the oxidant solution tank.