39
Maintenance and Care
7.4.1
Charge Batteries
Connect the charger to the battery
connector (Fig. 11/3) Charging
batteries is recommended if at least one
bar of the battery gauge has
extinguished after operation of the
machine. Observe the operating
instructions of the charger as well as
the operating instructions of the battery
manufacturer. In case it is intended to
change the type of battery the charger
has to be adjusted only by Minuteman
contract workshops.
Be sure to use the correct
battery charger per battery
type.
7.4.2
Charger Specifications
P/N: 957746-2
(36VDC, 25A, 120VAC Input,
Hi-frequency)
Charge the batteries properly
before starting the machine for
the first time. Minuteman
cannot be held liable for
battery damage resulting from
failure to initially charge
batteries.
Provide for sufficient
ventilation of areas where
batteries are charged. –
Explosion hazard! See section
1.5 of this manual for battery
and electrical precautions.
7.4.3
Maintenance of Batteries
Refer to battery manufacturers
instructions for information on care of
batteries.
7.4.4
Remove Batteries
1. Park machine on level ground.
2. Switch off machine by key switch.
3. Open empty recovery tank
(Fig. 11/2) and secure by strap
(Fig. 11/6).
4. Disconnect battery connector
(Fig. 11/3).
5. Disconnect battery connection
cables.
6. Remove batteries.
7.4.5 Install Batteries
Batteries must be selected and
seated appropriately in
accordance with factory
machine specifications. Failure
to do so could result in
inappropriate changes to the
machine's center of gravity
which, in turn, could result in
machine operation and control
hazards (especially on inclined
surfaces) and related personal
injury.
1. Switch off machine by key switch.
2. Open empty recovery tank(Fig. 11/2)
and secure by strap (Fig. 11/6).
3. Place batteries into tray according to
figure.
4. Connect battery poles and enclosed
connecting cables according to
battery connection/layout (Fig. 11/7).
Tighten and grease poles.
7.4.6 Disposal of Batteries
Used batteries labelled by the recycling
sign contain re-usable substances.
Such batteries must not be added to
normal household waste. Obtain local
information for the proper disposal of
used batteries.