Page 8
Ambassador Jr.
CONTROL PANELS
1. Vacuum switch
2. Brush switch
3. Pump spray switch, continuous operation position. Pump supplies solution to spray bar for
cleaning in large open areas.
4. Center position is “off ”.
5. Momentary position is for intermittent spray for cleaning in smaller more confi ned areas. When
released, switch will return to center off position.
6. Pump auxiliary when using separated fl oor tool or upholstery tool, switch must be switched
to on position. See fi gure 2 for solution hose hook up - aux. out.
7. Brush pressure adjustment gauge.
The brush adjustment knob is located in the lower left back panel. Adjustments made to the brush
pressure are shown on the brush pressure gauge (Item #7). Adjusting the brush past the green
zone on gauge will shorten brush and brush drive motor life.
1
2
3
4
5
6
7